EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Rapid On-Site Detection of Clarithromycin in Water Using an Evanescent Wave Fluorescence Immunosensor

Wenjing Zhang, Yuru Liu, Jingjing Liu iD, Feng Long, Hejie Li, Xinyu Zhang, Yuxiang Shi, Chunsheng Li iD

Biosensors · 2026

DOI: 10.3390/bios16100588 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Wenjing Zhang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cell Biochemistry Laboratory, Biology Institute of Hebei Academy of Sciences, Shijiazhuang 050081, China. Hauptthemen laut MEDLINE: Clarithromycin, Biosensing Techniques, Water Pollutants, Chemical. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Hebei Academy of Sciences, Science and Technology Program of Hebei Academy of Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Clarithromycin (CLA), a widely used macrolide antibiotic and contaminant of emerging concern (CEC), is frequently detected in aquatic environments. Its residues can induce bacterial antibiotic resistance, threatening public health and ecosystems. In this study, we constructed an evanescent wave fluorescence immunoassay for the rapid detection of clarithromycin. It detects CLA in water quickly, sensitively, and in a portable format. The sensor combines evanescent wave fluorescence with an indirect competitive immunoassay. It uses a CLA–bovine serum albumin (BSA) conjugate on an optical fiber bioprobe, along with a Cy5.5-labeled anti-clarithromycin monoclonal antibody (Ka = 7.40 × 109 L/mol) as the signal reporter. After optimization, the assay gave a linear range of 7.50–77.45 μg/L. The LOD was 1.67 μg/L, and the LOQ was 7.50 μg/L. The functionalized fiber bioprobe also held up well in repeated use. It stayed stable for over 200 regeneration cycles, with an RSD of 5.63%. The entire automated detection workflow was completed within 20 min without manual intervention. Real-sample validation was performed using tap water and river water spiked at 10, 30, and 60 μg/L, yielding recoveries ranging from 87.13% to 104.84%, with relative standard deviations below 13.08%. These results were corroborated by ELISA. These attributes, combined with the instrument’s portability and the probe’s regenerability, render this biosensor a promising analytical platform for on-site environmental monitoring of clarithromycin residues.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ClarithromycinBiosensing TechniquesWater Pollutants, ChemicalImmunoassayFluorescenceAnti-Bacterial AgentsLimit of DetectionWater

Stichwörter der Autor:innen

clarithromycinevanescent wave fluorescenceimmunosensoron-site detectionwater environment

Substanzen

ClarithromycinWater Pollutants, ChemicalAnti-Bacterial AgentsWater

Autor:innen und Institutionen

  • Cell Biochemistry Laboratory, Biology Institute of Hebei Academy of Sciences, Shijiazhuang 050081, China.
  • College of Life Science and Food Engineering, Hebei University of Engineering, Handan 056038, China.
  • School of Food Science and Biology, Hebei University of Science and Technology, Shijiazhuang 050018, China.
  • School of Chemistry and Life Resources, Renmin University of China, Beijing 100872, China.

ORCID-Profile: Jingjing Liu, Chunsheng Li

Förderung

  • Hebei Academy of Sciences
  • Science and Technology Program of Hebei Academy of Sciences

Zitieren

APA

Zhang, W., Liu, Y., Liu, J., Long, F., Li, H., Zhang, X., Shi, Y., & Li, C. (2026). Rapid On-Site Detection of Clarithromycin in Water Using an Evanescent Wave Fluorescence Immunosensor. Biosensors. https://doi.org/10.3390/bios16100588

Vancouver

Zhang W, Liu Y, Liu J, Long F, Li H, Zhang X, et al. Rapid On-Site Detection of Clarithromycin in Water Using an Evanescent Wave Fluorescence Immunosensor. Biosensors. 2026. doi:10.3390/bios16100588

BibTeX
@article{Zhang2026,
  author = {Zhang, Wenjing and Liu, Yuru and Liu, Jingjing and Long, Feng and Li, Hejie and Zhang, Xinyu and Shi, Yuxiang and Li, Chunsheng},
  title = {Rapid On-Site Detection of Clarithromycin in Water Using an Evanescent Wave Fluorescence Immunosensor},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16100588}
}
Kostenlos starten →