Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation
Biosensors · 2026
DOI: 10.3390/bios16100577 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Muhammad Awais und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea. Hauptthemen laut MEDLINE: Cornea, Biosensing Techniques. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, Gwangju Institute of Science and Technology.
Abstract (Originalsprache)
Non-contact detection of weak, transient acoustic signals is essential for photoacoustic and laser-ultrasound (LUS) bioimaging, including the assessment of corneal deformation and thickness variation. Passive 3 × 3 fiber-coupler interferometers provide phase-diverse sensing without external modulation; however, conventional ellipse-based calibration becomes unreliable when the measured phase excursion covers only a small fraction of the characteristic ellipse, as in nanometer-scale corneal responses. This study presents a physics-guided temporal convolutional network (PG-TCN) that directly maps two nonideal interferometric outputs to a continuous dynamic phase signal without ellipse fitting or separate phase unwrapping during inference. The model combines dilated one-dimensional convolutions with interferometric-consistency and temporal-regularization losses. Tests using PZT-modulated calibration signals acquired under several static chamber pressures of 10, 15, 20, and 25 kPa showed lower mean absolute error, higher normalized cross-correlation, and lower displacement RMSE than a CNN-LSTM baseline. In corneal-phantom LUS measurements, the first detected echo shifted from 4.632 to 4.488 µs between 10 and 20 kPa, corresponding to a relative thickness reduction of approximately 7.8 µm/kPa. The PG-TCN required 210 ± 18 µs per sequence while using approximately half the trainable parameters of the CNN-LSTM baseline. These results demonstrate a fast physics-guided optical detection framework for non-contact sensing of weak acoustic responses, supporting the use of 3 × 3 optical interferometry as a biosensing approach for LUS and photoacoustic applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering and Computer Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea.
- Korea Photonics Technology Institute, Gwangju 61007, Republic of Korea.
ORCID-Profile: Muhammad Awais, Byeong Ha Lee
Förderung
- Ministry of Science and ICT
- Gwangju Institute of Science and Technology
Zitieren
APA
Awais, M., Kim, Y., & Lee, B. H. (2026). Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation. Biosensors. https://doi.org/10.3390/bios16100577
Vancouver
Awais M, Kim Y, Lee BH. Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation. Biosensors. 2026. doi:10.3390/bios16100577
BibTeX
@article{Awais2026,
author = {Awais, Muhammad and Kim, Younggue and Lee, Byeong Ha},
title = {Physics-Guided Neural Phase Demodulation for Non-Contact Laser-Ultrasound Sensing of Corneal Phantom Deformation},
journal = {Biosensors},
year = {2026},
doi = {10.3390/bios16100577}
}