EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Melanin Bias in Cerebral fNIRS: A Monte Carlo Study Toward Equitable Optical Brain Sensing

Murad Althobaiti iD

Biosensors · 2026

DOI: 10.3390/bios16100538 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Murad Althobaiti. Beteiligte Einrichtung: Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia. Hauptthemen laut MEDLINE: Melanins, Biosensing Techniques, Brain. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Functional near-infrared spectroscopy (fNIRS) is an optical biosensing modality that transduces cortical hemodynamics into a measurable near-infrared signal, underpinning wearable brain monitors and brain–computer interfaces (BCIs). Because epidermal melanin is a strong near-infrared absorber, device sensitivity may depend on skin tone, raising an equity concern for optical neural biosensors. (1)

Objective

We quantify, by Monte Carlo simulation, how epidermal melanin biases the cerebral sensitivity of continuous-wave fNIRS biosensors across the Fitzpatrick scale, and evaluate source-wavelength selection as a device-level mitigation. (2)

Methods

Using a physically sourced melanin model and a two-stage design—an idealized layered slab for controlled sweeps and the Colin27 anatomical atlas for realistic-geometry confirmation—we computed gray-matter sensitivity for three skin tones, four wavelengths, and seven source–detector separations. (3)

Results

Melanin acts as a surface gate that lowers absolute cerebral sensitivity by up to ~12.5-fold (at 690 nm) for dark skin—and by ~5-fold at the 850 nm optimum—while preserving depth selectivity; longer wavelengths reduce the penalty (dark-skin retained sensitivity rising from 8.0% at 690 nm to 29.6% at 940 nm) but never remove it; and 850 nm is a practical optimum for single-wavelength cerebral sensitivity, combining the highest absolute sensitivity with improved equity, whereas 940 nm gains relative equity only as absolute signal collapses through water absorption. Atlas simulations reproduce the 850 nm optimum in realistic anatomy under identical optical assumptions and show that idealized slabs overestimate sensitivity ~50-fold and that sensitivity varies ~19-fold with probe placement. (4)

Conclusions

Skin tone and anatomy compound to disadvantage darker-skinned users of optical neural biosensors; wavelength selection and a sourced correction-factor framework offer concrete routes toward equitable device design.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MelaninsBiosensing TechniquesBrainMonte Carlo MethodSpectroscopy, Near-InfraredHumansBrain-Computer Interfaces

Stichwörter der Autor:innen

Fitzpatrick scaleMonte Carlobrain–computer interfacefunctional near-infrared spectroscopyhealth equitymelaninoptical biosensorskin tonewavelength optimizationwearable brain sensing

Substanzen

Melanins

Autor:innen und Institutionen

  • Department of Biomedical Engineering, College of Engineering, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia.

ORCID-Profile: Murad Althobaiti

Zitieren

APA

Althobaiti, M. (2026). Melanin Bias in Cerebral fNIRS: A Monte Carlo Study Toward Equitable Optical Brain Sensing. Biosensors. https://doi.org/10.3390/bios16100538

Vancouver

Althobaiti M. Melanin Bias in Cerebral fNIRS: A Monte Carlo Study Toward Equitable Optical Brain Sensing. Biosensors. 2026. doi:10.3390/bios16100538

BibTeX
@article{Althobaiti2026,
  author = {Althobaiti, Murad},
  title = {Melanin Bias in Cerebral fNIRS: A Monte Carlo Study Toward Equitable Optical Brain Sensing},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16100538}
}
Kostenlos starten →