Retention-Based, Dissociation-Sensitive Pre-Screening of Aptamers Using a Centrifugal Microspin Filter
Biosensors · 2026
DOI: 10.3390/bios16090510 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Cheeyoon Ahn und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Seoul 02841, Republic of Korea. Hauptthemen laut MEDLINE: Aptamers, Nucleotide, SELEX Aptamer Technique, Biosensing Techniques. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Science and ICT, Ministry of Education and Busan Metropolitan City, Korean government.
Abstract (Originalsprache)
Efficient evaluation of aptamer candidates after systematic evolution of ligands by exponential enrichment (SELEX) remains limited by the time and cost required for direct kinetic characterization. We developed a centrifugal microspin filtration (MSF)-based MSF–koff assay for retention-based, dissociation-sensitive pre-screening of aptamer candidates. Repeated washing preferentially removes rapidly dissociating aptamers from target-immobilized magnetic beads, and the retained aptamers are quantified by quantitative polymerase chain reaction and expressed as Wash 0-normalized retention (W0-NRT). In a thrombin aptamer panel, W0-NRT showed a strong inverse relationship with SPR-derived koff. A preliminary analysis of streptavidin aptamers likewise showed a W0-NRT-based ranking consistent with the literature-reported koff values, although the two target systems exhibited distinct empirical relationships. In a wash-based thrombin sandwich assay, two affinity-matched sensor aptamers differing 1.76-fold in koff were ranked in the same order by post-wash retention as by W0-NRT. The agreement was in rank order rather than in the magnitude of retention. The parallel microspin filter format was also estimated to offer advantages in analysis time and assay-related cost. The MSF–koff assay therefore provides a simple post-SELEX approach for prioritizing candidates with higher retention under dissociation-sensitive washing before detailed kinetic characterization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Biotechnology, College of Life Sciences and Biotechnology, Korea University, Seoul 02841, Republic of Korea.
ORCID-Profile: Hwayeon Jeong
Förderung
- Ministry of Science and ICT
- Ministry of Education and Busan Metropolitan City
- Korean government
- Ministry of Education and Busan Metropolitan City, Republic of Korea
Zitieren
APA
Ahn, C., Jeong, H., Jeon, K., & Jung, C. (2026). Retention-Based, Dissociation-Sensitive Pre-Screening of Aptamers Using a Centrifugal Microspin Filter. Biosensors. https://doi.org/10.3390/bios16090510
Vancouver
Ahn C, Jeong H, Jeon K, Jung C. Retention-Based, Dissociation-Sensitive Pre-Screening of Aptamers Using a Centrifugal Microspin Filter. Biosensors. 2026. doi:10.3390/bios16090510
BibTeX
@article{Ahn2026,
author = {Ahn, Cheeyoon and Jeong, Hwayeon and Jeon, Kyungjin and Jung, Cheulhee},
title = {Retention-Based, Dissociation-Sensitive Pre-Screening of Aptamers Using a Centrifugal Microspin Filter},
journal = {Biosensors},
year = {2026},
doi = {10.3390/bios16090510}
}
EUVIMED