EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

A Portable Colorimetric Biosensor Platform for Urinary Colorectal Cancer Biomarker Testing in Low-Resource Settings

Prashanthi Kovur, Scott MacKay, Songtian Bai, James Cook, Claudia Torres-Calzada, Dipanjan Bhattacharyya, Upasana Singh, David S. Wishart

Biosensors · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Early detection of colorectal cancer (CRC) is challenging in low-resource settings because access to colonoscopy and centralized laboratory testing is limited. Urine-based metabolite biomarkers offer a non-invasive alternative for CRC triage, but translating a laboratory assay into a point-of-care (PoC) system requires standardized fluid handling, operator-independent timing, field-compatible reagents, and quantitative calibration. Here, we present a low-cost, semi-automated PoC platform integrating a validated, sequential, three-metabolite CRC-biomarker assay with robotic fluid handling, a motorized chromatographic module, an optical reader, Bluetooth electronics, and tablet-guided control. The platform measures urinary diacetylspermine and hippuric acid, with creatinine serving as a normalization reference, and reports absolute quantitative concentrations. Automated dilution, tube positioning, timed incubation, controlled column elution, and software-guided transfer reduce operator-dependent variation. Using pooled urine samples spiked at clinically relevant concentrations, the creatinine assay showed a strong quadratic response (0–50 mM, R2 = 0.998), as did the diacetylspermine assay (0–4 μM, R2 = 0.979), while the hippuric acid assay showed a linear response of R2 = 0.989. The RGB sensor tracked the concentration-dependent trend observed with a laboratory microplate reader (R2 = 0.968–0.999). Reagents reformulated as lyophilized or pre-weighed, vacuum-sealed kits withstood accelerated heat and humidity (45 °C/70% RH) testing and international shipping to the pilot site very well. At approximately USD 490 for the complete instrument (including tablet) and roughly USD 7.65 in consumables per screening test, the platform offers a practical, quantitative, and portable route for decentralized CRC screening.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Prashanthi Kovur, Scott MacKay, Songtian Bai, James Cook, Claudia Torres-Calzada, Dipanjan Bhattacharyya, Upasana Singh, David S. Wishart
Quelle
Biosensors
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
2079-6374
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Prashanthi Kovur, Scott MacKay, Songtian Bai, James Cook, Claudia Torres-Calzada, Dipanjan Bhattacharyya, Upasana Singh, David S. Wishart (2026). A Portable Colorimetric Biosensor Platform for Urinary Colorectal Cancer Biomarker Testing in Low-Resource Settings. Biosensors. https://doi.org/10.3390/bios16090485
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1