EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Recent Progress in Nanoparticle-Based Biosensors for Monitoring Shigella spp. in Food Safety: A Critical Review

Sumeyra Savas iD, Seyed Mohammad Taghi Gharibzahedi iD

Biosensors · 11.08.2026 · 16 (8) · 435

DOI: 10.3390/bios16080435 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Biosensors, online erschienen am 11.08.2026. Verfasst von Sumeyra Savas und 1 weiteren Autor:innen. Beteiligte Einrichtung: Biosensors and Biotechnology Laboratory (BBL), Medical School, Bandırma Onyedi Eylül University, Bandırma 10200, Balıkesir, Türkiye. Hauptthemen laut MEDLINE: Biosensing Techniques, Shigella, Food Safety, Nanoparticles. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 108 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Bandırma Onyedi Eylül University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Shigella is a foodborne bacterial pathogen with a low infectious dose and significant public health impact. Culture-based and molecular techniques provide reliable identification but are time-consuming. Nanoparticle-based biosensors offer sensitive, selective, and compact alternatives. Recent advances in nanoparticle-based biosensors for Shigella spp. (S. flexneri, S. sonnei, S. dysenteriae, and S. boydii) detection have been reviewed in terms of signal amplification, biorecognition, biological targets, sensor types, and performance in real food matrices. Detection strategies rely on gene-level and whole-cell recognition. Targeting virulence genes, invasion plasmid antigen H (ipaH), provides stable genus-level identification, whereas whole-cell recognition facilitates rapid detection without extensive sample preparation. Optical biosensors, including fluorescence-based methods, surface-enhanced Raman spectroscopy (SERS), and localized surface plasmon resonance (LSPR), achieve low detection limits with strong tolerance to complex food matrices. Electrochemical biosensors offer operational simplicity, portability, and suitability for food screening. Lateral flow and hybrid systems provide rapid detection through simplified assay formats and visual readout, with performance influenced by the balance between speed and sensitivity. Validation in real food matrices shows acceptable recoveries, minimal cross-reactivity, and agreement with reference methods. This overview provides a design-oriented framework for nanoparticle-based biosensor selection in food safety by integrating nanomaterial function, biosensor design, and performance characteristics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesShigellaFood SafetyNanoparticlesFood MicrobiologyHumansSurface Plasmon Resonance

Stichwörter der Autor:innen

Shigella speciesfood contamination monitoringfoodborne pathogen detectiongene-level biosensingnanobiosensorspoint-of-care detection

Autor:innen und Institutionen

  • Biosensors and Biotechnology Laboratory (BBL), Medical School, Bandırma Onyedi Eylül University, Bandırma 10200, Balıkesir, Türkiye.
  • Institute of Materials Science, Faculty of Engineering, Kiel University, 24143 Kiel, Germany.

ORCID-Profile: Sumeyra Savas, Seyed Mohammad Taghi Gharibzahedi

Förderung

  • Bandırma Onyedi Eylül University

Zitieren

APA

Savas, S., & Gharibzahedi, S. M. T. (2026). Recent Progress in Nanoparticle-Based Biosensors for Monitoring Shigella spp. in Food Safety: A Critical Review. Biosensors, 16(8), 435. https://doi.org/10.3390/bios16080435

Vancouver

Savas S, Gharibzahedi SMT. Recent Progress in Nanoparticle-Based Biosensors for Monitoring Shigella spp. in Food Safety: A Critical Review. Biosensors. 2026;16(8):435. doi:10.3390/bios16080435

BibTeX
@article{Savas2026,
  author = {Savas, Sumeyra and Gharibzahedi, Seyed Mohammad Taghi},
  title = {Recent Progress in Nanoparticle-Based Biosensors for Monitoring Shigella spp. in Food Safety: A Critical Review},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {8},
  pages = {435},
  doi = {10.3390/bios16080435}
}
Kostenlos starten →