Electric-Field-Assisted Co-Deposition of Bacteriorhodopsin and PEDOT:PSS on Interdigitated Electrodes for Biohybrid Photodetectors
Biosensors · 22.07.2026 · 16 (7) · 398
DOI: 10.3390/bios16070398 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 22.07.2026. Verfasst von Abraham Ruiz Gómez und 4 weiteren Autor:innen. Beteiligte Einrichtung: Communications Engineering Department, Miguel Hernandez University, 03202 Elche, Spain. Hauptthemen laut MEDLINE: Bacteriorhodopsins, Biosensing Techniques, Polystyrenes. Die Arbeit nennt 83 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: State 469 Investigation Agency, Spain, Conselleria d'Educació, Universitats i Ocupació, Generalitat Valenciana, Conselleria d’Educació, Universitats i Ocupació, Generalitat Valenciana.
Abstract (Originalsprache)
This work presents the fabrication and characterization of biohybrid optoelectronic devices based on the integration of bacteriorhodopsin (bR) and PEDOT:PSS on interdigitated electrodes (IDEs). A three-phase methodology was developed to systematically optimize the active layer. First, the effect of an electric field applied during PEDOT:PSS drying was investigated, identifying a drying voltage of 1.2 V as the optimum among the tested conditions, achieving a maximum responsivity of (35.65±1.36) mA/W, a minimum noise equivalent power of (5.99±0.13)×10−10 W·Hz−1/2, and a maximum specific detectivity of (3.55±0.07)×108 cm Hz1/2W−1. Second, the compatibility of a physiological buffer for bR stabilization was assessed, demonstrating that a 60% PEDOT:PSS/40% buffer composition preserved and further improved the optoelectronic performance of the polymer matrix. Finally, bacteriorhodopsin was incorporated into the optimized PEDOT:PSS/buffer formulation, yielding the hybrid bR_1.2V_60% device, which exhibited an on/off ratio of 2.45 at 0 V and a maximum responsivity of (5.63±0.76) mA/W under reverse bias. Morphological analysis suggested improved film homogeneity, together with a continuous polymer matrix containing dispersed crystalline buffer-salt inclusions. Dynamic measurements showed a stable and reversible short-term photoresponse over successive illumination cycles (ΔION=18.54±0.17μA) with full baseline recovery. These results demonstrate a scalable strategy for the development of biohybrid photodetectors with potential for low-power and sustainable optoelectronic applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Communications Engineering Department, Miguel Hernandez University, 03202 Elche, Spain.
- University Institute for Engineering Research, Miguel Hernandez University, 03202 Elche, Spain.
ORCID-Profile: Abraham Ruiz Gómez, Juan Carlos Ferrer Millán, José Luis Alonso Serrano, Alba Hortal Foronda, Susana Fernández de Ávila López
Förderung
- State 469 Investigation Agency, Spain
- Conselleria d'Educació, Universitats i Ocupació, Generalitat Valenciana
- Conselleria d’Educació, Universitats i Ocupació, Generalitat Valenciana
- State Investigation Agency
Zitieren
APA
Gómez, A. R., Millán, J. C. F., Serrano, J. L. A., Foronda, A. H., & López, S. F. Á. (2026). Electric-Field-Assisted Co-Deposition of Bacteriorhodopsin and PEDOT:PSS on Interdigitated Electrodes for Biohybrid Photodetectors. Biosensors, 16(7), 398. https://doi.org/10.3390/bios16070398
Vancouver
Gómez AR, Millán JCF, Serrano JLA, Foronda AH, López SFÁ. Electric-Field-Assisted Co-Deposition of Bacteriorhodopsin and PEDOT:PSS on Interdigitated Electrodes for Biohybrid Photodetectors. Biosensors. 2026;16(7):398. doi:10.3390/bios16070398
BibTeX
@article{Gmez2026,
author = {Gómez, Abraham Ruiz and Millán, Juan Carlos Ferrer and Serrano, José Luis Alonso and Foronda, Alba Hortal and López, Susana Fernández de Ávila},
title = {Electric-Field-Assisted Co-Deposition of Bacteriorhodopsin and PEDOT:PSS on Interdigitated Electrodes for Biohybrid Photodetectors},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {7},
pages = {398},
doi = {10.3390/bios16070398}
}
EUVIMED