EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Universal, Rapid, and Cleavable Labeling of Antibodies by Fluorophores and DNA Oligonucleotides for Multiplex Immunostaining and Spatial Proteomics Through MIST Linker

Arafat Meah iD, Shuo Yin iD, Saimoen Strrrz Anderson, Ming Lin iD, Shuo Liang, Meghana Davuluri, Yi-Xian Qin, Sandeep K Mallipattu, Jun Wang

Biosensors · 15.07.2026 · 16 (7) · 385

DOI: 10.3390/bios16070385 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 15.07.2026. Verfasst von Arafat Meah und 8 weiteren Autor:innen. Beteiligte Einrichtung: Multiplex Biotechnology Laboratory, Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794, USA. Hauptthemen laut MEDLINE: Proteomics, Oligonucleotides, Antibodies, Fluorescent Dyes. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIGMS NIH HHS, Dialysis Clinic, NIDDK NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Direct antibody labeling is essential for immunoassays, multiplexed imaging, and biosensing; however, current methods are often time-consuming, restricted by antibody source, risk compromising protein performance, or vary with multiple steps. We introduce multiplex in situ tagging (MIST) Linker, a rapid and Fc-site-specific labeling tool that conjugates fluorophores or DNA oligonucleotides to antibodies from diverse commercial sources in as fast as 10 min using minimal starting material. MIST Linker achieves >90% cleavage upon UV exposure, facilitating rapid cyclic imaging on a single specimen. Validated across multiple species and sources, the platform outperforms conventional two-step immunofluorescence and immunohistochemistry in various tissues and cell lines. By enabling the rapid, cost-effective customization of antibody panels, MIST Linker significantly lowers the barrier to accessing antibody–DNA conjugates for spatial biology. When integrated with the spatial MIST platform and MIST-Explorer, it enables high-plex, single-cell spatial proteomics at high signal-to-noise ratios in human clinical biopsies, mouse specimens and cell lines. This toolkit provides an efficient, accessible solution for high-resolution spatial mapping, allowing for the in-depth analysis of cell subpopulations, biomarker distributions, and signaling events in complex biological specimens. Thus, MIST Linker offers a versatile, accessible, and scalable solution for antibody-labeling-based research and clinical diagnosis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProteomicsOligonucleotidesAntibodiesFluorescent DyesHumansAnimalsMiceDNAImmunohistochemistryStaining and LabelingBiosensing Techniques

Stichwörter der Autor:innen

MIST Linkerantibody labelingnanobody labelingphotocleavable linkersingle cell analysisspatial proteomics

Substanzen

OligonucleotidesAntibodiesFluorescent DyesDNA

Autor:innen und Institutionen

  • Multiplex Biotechnology Laboratory, Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794, USA.
  • Department of Computer Science, State University of New York at Stony Brook, Stony Brook, NY 11794, USA.
  • Department of Biomedical Engineering, State University of New York at Stony Brook, Stony Brook, NY 11794, USA.
  • Division of Nephrology and Hypertension, Department of Medicine, Stony Brook School of Medicine, Stony Brook, NY 11794, USA.
  • Renal Section, Northport VA Medical Center, Northport, NY 11768, USA.
  • MIST Bioscience, New York, NY 11794, USA.

ORCID-Profile: Arafat Meah, Shuo Yin, Ming Lin

Förderung

  • NIGMS NIH HHS
  • Dialysis Clinic
  • NIDDK NIH HHS
  • Stony Brook University
  • NIA NIH HHS
  • United States Department of Veterans Affairs
  • BLRD VA
  • U.S. National Science Foundation

Zitieren

APA

Meah, A., Yin, S., Anderson, S. S., Lin, M., Liang, S., Davuluri, M., Qin, Y. X., Mallipattu, S. K., & Wang, J. (2026). Universal, Rapid, and Cleavable Labeling of Antibodies by Fluorophores and DNA Oligonucleotides for Multiplex Immunostaining and Spatial Proteomics Through MIST Linker. Biosensors, 16(7), 385. https://doi.org/10.3390/bios16070385

Vancouver

Meah A, Yin S, Anderson SS, Lin M, Liang S, Davuluri M, et al. Universal, Rapid, and Cleavable Labeling of Antibodies by Fluorophores and DNA Oligonucleotides for Multiplex Immunostaining and Spatial Proteomics Through MIST Linker. Biosensors. 2026;16(7):385. doi:10.3390/bios16070385

BibTeX
@article{Meah2026,
  author = {Meah, Arafat and Yin, Shuo and Anderson, Saimoen Strrrz and Lin, Ming and Liang, Shuo and Davuluri, Meghana and Qin, Yi-Xian and Mallipattu, Sandeep K and Wang, Jun},
  title = {Universal, Rapid, and Cleavable Labeling of Antibodies by Fluorophores and DNA Oligonucleotides for Multiplex Immunostaining and Spatial Proteomics Through MIST Linker},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {385},
  doi = {10.3390/bios16070385}
}
Kostenlos starten →