EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Agreement and Reliability of a Digital Incentive Spirometer Compared with a Volume-Oriented Incentive Spirometry Device Across Different Age Groups

Kornanong Yuenyongchaiwat iD, Lucksanaporn Mahawong, Chaopraya Nenmanee, Sasipa Buranapuntalug iD, Chusak Thanawattano iD

Biosensors · 29.06.2026 · 16 (7) · 361

DOI: 10.3390/bios16070361 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Biosensors, online erschienen am 29.06.2026. Verfasst von Kornanong Yuenyongchaiwat und 4 weiteren Autor:innen. Beteiligte Einrichtung: Physiotherapy Department, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani 12120, Thailand. Hauptthemen laut MEDLINE: Spirometry, Lung Volume Measurements, Digital Technology. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Council of Thailand.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Incentive spirometry is widely used in respiratory rehabilitation to enhance lung expansion and prevent postoperative pulmonary complications. However, conventional devices, including volume-oriented and flow-oriented incentive spirometers, rely on subjective visual interpretation, which may limit measurement accuracy and clinical utility. A digital incentive spirometer (DIS) has been developed to provide objective, real-time measurements of inspiratory volume. This study aimed to evaluate the agreement and reliability between the DIS and a volume-oriented incentive spirometer (VIS) across different age groups. A cross-sectional study was conducted in 150 participants aged 7–80 years, stratified into five age groups with equal sex distribution. Inspiratory volume was measured simultaneously using both devices. Agreement was assessed using Bland–Altman analysis, and reliability was evaluated using intraclass correlation coefficients (ICC). The DIS demonstrated good overall reliability (ICC = 0.868, 95% CI: 0.821–0.903). The mean difference was 48.69 mL, indicating slight overestimation by the DIS. However, the limits of agreement were wide (−469.24 to 566.63 mL), suggesting limited interchangeability. Reliability varied across age groups, with the highest ICC in older adults and the lowest in adolescents. The DIS showed good reliability but limited agreement with the VIS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SpirometryLung Volume MeasurementsDigital TechnologyReproducibility of ResultsCross-Sectional StudiesHumansMaleFemaleChildAdolescentYoung AdultAdultMiddle AgedAgedAged, 80 and overAge Factors

Stichwörter der Autor:innen

digital healthhealthcare innovationincentive spirometerinspiratory volumemedical device

Autor:innen und Institutionen

  • Physiotherapy Department, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani 12120, Thailand.
  • Thammasat University Research Unit for Physical Therapy in Respiratory and Cardiovascular Systems, Thammasat University, Pathum Thani 12120, Thailand.
  • Biomedical Electronics and Systems Research Team, Assistive Technology and Medical Devices Research Group, National Electronics and Computer Technology Center (NECTEC), Pathum Thani 12120, Thailand.

ORCID-Profile: Kornanong Yuenyongchaiwat, Sasipa Buranapuntalug, Chusak Thanawattano

Förderung

  • National Research Council of Thailand

Zitieren

APA

Yuenyongchaiwat, K., Mahawong, L., Nenmanee, C., Buranapuntalug, S., & Thanawattano, C. (2026). Agreement and Reliability of a Digital Incentive Spirometer Compared with a Volume-Oriented Incentive Spirometry Device Across Different Age Groups. Biosensors, 16(7), 361. https://doi.org/10.3390/bios16070361

Vancouver

Yuenyongchaiwat K, Mahawong L, Nenmanee C, Buranapuntalug S, Thanawattano C. Agreement and Reliability of a Digital Incentive Spirometer Compared with a Volume-Oriented Incentive Spirometry Device Across Different Age Groups. Biosensors. 2026;16(7):361. doi:10.3390/bios16070361

BibTeX
@article{Yuenyongchaiwat2026,
  author = {Yuenyongchaiwat, Kornanong and Mahawong, Lucksanaporn and Nenmanee, Chaopraya and Buranapuntalug, Sasipa and Thanawattano, Chusak},
  title = {Agreement and Reliability of a Digital Incentive Spirometer Compared with a Volume-Oriented Incentive Spirometry Device Across Different Age Groups},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {361},
  doi = {10.3390/bios16070361}
}
Kostenlos starten →