EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Application of Aptamer–Carbon Surfaces for Electrochemical Label-Free Detection of Vancomycin

Izabela Zaras iD, Piotr Pieta iD, Marta Jarczewska

Biosensors · 24.06.2026 · 16 (7) · 353

DOI: 10.3390/bios16070353 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 24.06.2026. Verfasst von Izabela Zaras und 2 weiteren Autor:innen. Beteiligte Einrichtung: Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland. Hauptthemen laut MEDLINE: Vancomycin, Aptamers, Nucleotide, Biosensing Techniques, Electrochemical Techniques. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Warsaw University of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Gold is considered the most widely used surface for the development of aptamer-based layers. However, its high cost, laborious surface-cleaning protocols, and susceptibility of receptor layers to degradation in complex samples, including biological fluids, enforce the search for alternative transducers. One solution is the application of carbon materials, which are inexpensive and allow for the use of a wide potential range when electrochemical measurements are performed. Herein, we present studies on the elaboration of aptamer receptor layers formed on carbon macroelectrodes. To achieve this, a one-step procedure for aptamer molecules containing a pyrene or anthracene group at the 5′ end was used, with immobilization via adsorption facilitated by Π–Π interactions between the anchor group and the carbon surface. It was evidenced that using anthracene-modified aptamer and sodium anthraquinone-2-sulfonic acid (AQMS) redox indicator enabled the detection of a model analyte–vancomycin below the millimolar concentration range. It was also revealed that vancomycin can be successfully detected in serum samples, and the aptasensor exhibits good selectivity towards vancomycin. The latter was observed by comparison of responses in PBS containing solely vancomycin and a solution spiked with vancomycin and a mixture of antibiotics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

VancomycinAptamers, NucleotideBiosensing TechniquesElectrochemical TechniquesCarbonElectrodesAnthraquinones

Stichwörter der Autor:innen

aptamercarbon-based electrodesredox indicatorvancomycin

Substanzen

VancomycinAptamers, NucleotideCarbonAnthraquinones

Autor:innen und Institutionen

  • Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland.
  • Institute of Physical Chemistry, Polish Academy of Sciences, Kasprzaka 44/52, 01-224 Warsaw, Poland.

ORCID-Profile: Izabela Zaras, Piotr Pieta

Förderung

  • Warsaw University of Technology

Zitieren

APA

Zaras, I., Pieta, P., & Jarczewska, M. (2026). Application of Aptamer–Carbon Surfaces for Electrochemical Label-Free Detection of Vancomycin. Biosensors, 16(7), 353. https://doi.org/10.3390/bios16070353

Vancouver

Zaras I, Pieta P, Jarczewska M. Application of Aptamer–Carbon Surfaces for Electrochemical Label-Free Detection of Vancomycin. Biosensors. 2026;16(7):353. doi:10.3390/bios16070353

BibTeX
@article{Zaras2026,
  author = {Zaras, Izabela and Pieta, Piotr and Jarczewska, Marta},
  title = {Application of Aptamer–Carbon Surfaces for Electrochemical Label-Free Detection of Vancomycin},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {7},
  pages = {353},
  doi = {10.3390/bios16070353}
}
Kostenlos starten →