Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 03.06.2026. Verfasst von Po-Chung Chen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomechatronic Engineering, National Ilan University, Yilan City 260007, Taiwan. Hauptthemen laut MEDLINE: Gliadin, Biosensing Techniques, Aptamers, Nucleotide. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Celiac patients require strict avoidance of gliadin, the primary immunotoxic component of gluten, making sensitive detection essential for food safety. A label-free and reagentless capacitive aptasensor for gliadin detection was developed using an aminated polyethylene terephthalate (PET) thin film as both an insulating layer and functionalization platform. The PET surface was modified via ethylenediamine-mediated aminolysis, enabling covalent immobilization of 5′-NH2-modified gliadin aptamers through glutaraldehyde crosslinking. Under optimized conditions (23 µm initial PET thickness and 10 µM aptamer), the sensor showed a linear response from 10 to 500 µg/mL gliadin (R2 = 0.9792), with a detection limit of 6.0 µg/mL, equivalent to 12 ppm gluten, which is well below the regulatory threshold of 20 ppm for gluten-free labeling. The aptasensor showed excellent correlation with commercial ELISA for 20 gluten-containing soy sauce samples (R2 = 0.926) and spike recoveries of 91.7–105.7% in two gluten-free products. Efficient regeneration was achieved with 25 mM arginine (pH 9.0), retaining >80% activity after six cycles. This simple, low-cost, and reusable platform relies solely on a single PET thin film as consumable in a custom-built system with lab-friendly aminolysis conditions. It substantially lowers barriers to functionalized insulating layer fabrication, the primary challenge in capacitive aptasensor development, providing a promising method for on-site gliadin monitoring in gluten-free food safety applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GliadinBiosensing TechniquesAptamers, NucleotidePolyethylene TerephthalatesLimit of DetectionHumans

Stichwörter der Autor:innen

aminolysisglutenlabel-freereagentlessregenerationsoy sauce

Substanzen

GliadinPolyethylene TerephthalatesAptamers, Nucleotide

Autor:innen und Institutionen

  • Department of Biomechatronic Engineering, National Ilan University, Yilan City 260007, Taiwan.
  • Department of Biomechatronics Engineering, National Taiwan University, Taipei 106319, Taiwan.

ORCID-Profile: Po-Chuan Hsieh

Förderung

  • National Science and Technology Council

Zitieren

APA

Chen, P. C., & Hsieh, P. C. (2026). Aminated PET Thin Film as a Functionalized Insulating Layer for Capacitive Gliadin Aptasensor Construction. Biosensors, 16(6), 324. https://doi.org/10.3390/bios16060324

Vancouver

Chen PC, Hsieh PC. Aminated PET Thin Film as a Functionalized Insulating Layer for Capacitive Gliadin Aptasensor Construction. Biosensors. 2026;16(6):324. doi:10.3390/bios16060324

BibTeX
@article{Chen2026,
  author = {Chen, Po-Chung and Hsieh, Po-Chuan},
  title = {Aminated PET Thin Film as a Functionalized Insulating Layer for Capacitive Gliadin Aptasensor Construction},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {6},
  pages = {324},
  doi = {10.3390/bios16060324}
}