EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A Centrifugal Microfluidic Platform Integrating Immunomagnetic Separation and Isothermal Amplification for Rapid and High-Sensitivity Detection of Foodborne Pathogens

Qingfeng Zheng, Zhun Zhuang, Hua Lei, Jianhan Lin iD, Hua Yang, Ruibin Hu

Biosensors · 02.06.2026 · 16 (6) · 321

DOI: 10.3390/bios16060321 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 02.06.2026. Verfasst von Qingfeng Zheng und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biotechnology, Xianghu Laboratory, Hangzhou 311231, China. Hauptthemen laut MEDLINE: Immunomagnetic Separation, Food Microbiology, Biosensing Techniques. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the Key Research Program in the Field of Agriculture and Social Development of Hangzhou, Hangzhou Natural Science Foundation Program Project, Key Research Program in the Field of Agriculture and Social Development of Hangzhou.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The contamination by foodborne pathogens posed a significant health threat and huge economic burden. Traditional detection methods were limited by cumbersome and time-consuming procedures, low automation, and reliance on expensive instrumentation, making them inadequate for on-site detection. This paper presented a centrifugal microfluidic chip that integrated sample pretreatment, nucleic acid extraction, amplification reaction, and signal detection. The chip featured an innovative design that combined a bursting valve with the siphon channel and employed a dual-channel configuration for splitting and directing the flow of different reagents, thereby overcoming the instability issue of unintended pre-activation or interruption that often occurred in the cascade design of multilevel siphon channels. Moreover, by synergistically combining with immunomagnetic separation as well as multi-enzyme isothermal rapid amplification, a portable, easy, rapid, high-sensitivity, and low-cost point-of-care testing (POCT) system for foodborne pathogens was developed. Under optimized conditions, the system enabled detection of Salmonella in spiked milk samples at 10 CFU/mL in 1 h. The recoveries ranged from 83.22% to 127.60%, with relative standard deviations of ≤13.7%, indicating that this system had great potential for rapid and high-sensitivity detection of foodborne pathogens in resource-limited settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Immunomagnetic SeparationFood MicrobiologyBiosensing TechniquesNucleic Acid Amplification TechniquesAnimalsLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesMicrofluidicsCentrifugationMilkSalmonellaRapid Diagnostic Tests

Stichwörter der Autor:innen

centrifugal microfluidic chipfoodborne pathogensimmunomagnetic separationmultienzyme isothermal rapid amplificationpoint-of-care testing

Autor:innen und Institutionen

  • Institute of Biotechnology, Xianghu Laboratory, Hangzhou 311231, China.
  • College of Information and Electrical Engineering, China Agricultural University, Beijing 100083, China.
  • Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China.

ORCID-Profile: Jianhan Lin

Förderung

  • the Key Research Program in the Field of Agriculture and Social Development of Hangzhou
  • Hangzhou Natural Science Foundation Program Project
  • Key Research Program in the Field of Agriculture and Social Development of Hangzhou

Zitieren

APA

Zheng, Q., Zhuang, Z., Lei, H., Lin, J., Yang, H., & Hu, R. (2026). A Centrifugal Microfluidic Platform Integrating Immunomagnetic Separation and Isothermal Amplification for Rapid and High-Sensitivity Detection of Foodborne Pathogens. Biosensors, 16(6), 321. https://doi.org/10.3390/bios16060321

Vancouver

Zheng Q, Zhuang Z, Lei H, Lin J, Yang H, Hu R. A Centrifugal Microfluidic Platform Integrating Immunomagnetic Separation and Isothermal Amplification for Rapid and High-Sensitivity Detection of Foodborne Pathogens. Biosensors. 2026;16(6):321. doi:10.3390/bios16060321

BibTeX
@article{Zheng2026,
  author = {Zheng, Qingfeng and Zhuang, Zhun and Lei, Hua and Lin, Jianhan and Yang, Hua and Hu, Ruibin},
  title = {A Centrifugal Microfluidic Platform Integrating Immunomagnetic Separation and Isothermal Amplification for Rapid and High-Sensitivity Detection of Foodborne Pathogens},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {6},
  pages = {321},
  doi = {10.3390/bios16060321}
}
Kostenlos starten →