EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Catalytic Reduction of H2O2 by Polyvinylpyrrolidone Nickel Oxide Nanozymatic Activity and Colorimetric Sensing of Ascorbic Acid

Mosebudi Rambevha iD, Ridge Chavalala iD, Philani Mashazi iD

Biosensors · 21.05.2026 · 16 (5) · 299

DOI: 10.3390/bios16050299 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 21.05.2026. Verfasst von Mosebudi Rambevha und 2 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Nanotechnology Innovation, Rhodes University, P.O. Box 94, Makhanda 6140, South Africa. Hauptthemen laut MEDLINE: Ascorbic Acid, Hydrogen Peroxide, Biosensing Techniques. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Technology Innovation Agency, Department of Science Technology and Innovation, National Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ascorbic acid (AA) or vitamin C is an important biomolecule that plays a crucial role in biological and physiological systems. Deficiency and/or excess of AA in the body can lead to severe diseases such as scurvy and gastrointestinal complications. Therefore, it is crucial to monitor the levels of AA in the body and supplements. Polyvinylpyrrolidone nickel oxide nanoparticles (PVP-NiONPs) are prepared and evaluated for their potential as nanozymes with peroxidase-like activity. o-Phenylenediamine (OPD) was used as a chromogen in the presence of hydrogen peroxide. The oxidized OPD was produced by ROS from PVP-NiONPs and H2O2. This was monitored using UV-vis spectra and by colour changes using the naked eye. AA reduced the oxidized OPD during its sensing. The UV-vis signal was linear for AA concentrations ranging from 40 µM to 400 μM. The limit of detection (LOD) for AA was calculated to be 0.11 μM using 3σ and the limit of quantification (LOQ) was 0.36 μM using 10σ indicating a very high sensitivity. The colorimetric sensor showed good reproducibility and a recovery rate between 92.3% and 102.6%, indicating high accuracy and reliability. The findings of this work confirmed that PVP-NiONPs possess enzyme-like activity and are a promising alternative for the quantitative, on-site detection of ascorbic acid.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ascorbic AcidHydrogen PeroxideBiosensing TechniquesColorimetryNickelPovidoneCatalysisOxidation-ReductionLimit of DetectionNanoparticles

Stichwörter der Autor:innen

ascorbic acidcolorimetric sensornanozymesnickel oxide nanoparticlespolyvinylpyrrolidone

Substanzen

Ascorbic AcidNickelHydrogen PeroxidePovidonenickel monoxide

Autor:innen und Institutionen

  • Institute for Nanotechnology Innovation, Rhodes University, P.O. Box 94, Makhanda 6140, South Africa.

ORCID-Profile: Mosebudi Rambevha, Ridge Chavalala, Philani Mashazi

Förderung

  • Technology Innovation Agency
  • Department of Science Technology and Innovation
  • National Research Foundation
  • DST/Mintek Nanotechnology Innovation Centre
  • Rhodes University
  • Department of Science, Technology and Innovation

Zitieren

APA

Rambevha, M., Chavalala, R., & Mashazi, P. (2026). Catalytic Reduction of H2O2 by Polyvinylpyrrolidone Nickel Oxide Nanozymatic Activity and Colorimetric Sensing of Ascorbic Acid. Biosensors, 16(5), 299. https://doi.org/10.3390/bios16050299

Vancouver

Rambevha M, Chavalala R, Mashazi P. Catalytic Reduction of H2O2 by Polyvinylpyrrolidone Nickel Oxide Nanozymatic Activity and Colorimetric Sensing of Ascorbic Acid. Biosensors. 2026;16(5):299. doi:10.3390/bios16050299

BibTeX
@article{Rambevha2026,
  author = {Rambevha, Mosebudi and Chavalala, Ridge and Mashazi, Philani},
  title = {Catalytic Reduction of H2O2 by Polyvinylpyrrolidone Nickel Oxide Nanozymatic Activity and Colorimetric Sensing of Ascorbic Acid},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {299},
  doi = {10.3390/bios16050299}
}
Kostenlos starten →