Low-Effort Respiratory Function Estimation with a Soft Wearable Digital Spirometry Patch
Biosensors · 08.05.2026 · 16 (5) · 272
DOI: 10.3390/bios16050272 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 08.05.2026. Verfasst von Faheem A Karim und 9 weiteren Autor:innen. Beteiligte Einrichtung: Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA. Hauptthemen laut MEDLINE: Spirometry, Wearable Electronic Devices, Respiratory Function Tests, Biosensing Techniques. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health.
Abstract (Originalsprache)
Spirometry is widely regarded as the clinical gold standard for quantifying lung function. It plays a central role in the diagnosis and management of cardiopulmonary disorders, including asthma and chronic obstructive pulmonary disease (COPD). However, the procedure relies on a forceful and often stressful expiratory maneuver that may cause patient discomfort and require substantial effort, frequently necessitating active coaching and trained personnel to ensure reproducible measurements. In this paper, we present the Digital Spirometry Patch (DSP), a soft, flexible, wearable patch capable of estimating lung function parameters by utilizing low-effort breathing maneuvers. Eighteen participants performed low-effort and forceful breathing maneuvers while wearing the DSP to collect tracheal sound and chest movement signals for spirometric parameter estimation using elastic net and simple linear regression. Using leave-one-subject-out cross-validation, the elastic net models achieved RMSEs of 0.668 L, 0.224 L, and 0.428 L/s for FVC, FEV1, and PEF, respectively, using low-effort breathing maneuvers, and 0.499 L, 0.304 L, and 0.891 L/s using forceful exhalation maneuvers. These results demonstrate the potential of the DSP as a wearable, low-effort alternative for estimating lung function outside of conventional spirometry settings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
- BioMedical Engineering and Imaging Institute, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
- George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA.
- Center for Biostatistics, Department of Population Health Science and Policy, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
- Icahn Institute for Data Science and Genomic Technology, Icahn School of Medicine at Mount Sinai, New York, NY 10029, USA.
ORCID-Profile: Faheem A Karim, Ahmed Tariq, Christopher B Fitzpatrick, Helena Schotland, Yoon Jae Lee, Woon-Hong Yeo, Yun Soung Kim
Förderung
- NIBIB NIH HHS
- National Institute of Biomedical Imaging and Bioengineering
- National Institutes of Health
Zitieren
APA
Karim, F. A., Tariq, A., Fitzpatrick, C. B., Zhou, L., Suárez-Fariñas, M., Schotland, H., Rogers, L., Lee, Y. J., Yeo, W. H., & Kim, Y. S. (2026). Low-Effort Respiratory Function Estimation with a Soft Wearable Digital Spirometry Patch. Biosensors, 16(5), 272. https://doi.org/10.3390/bios16050272
Vancouver
Karim FA, Tariq A, Fitzpatrick CB, Zhou L, Suárez-Fariñas M, Schotland H, et al. Low-Effort Respiratory Function Estimation with a Soft Wearable Digital Spirometry Patch. Biosensors. 2026;16(5):272. doi:10.3390/bios16050272
BibTeX
@article{Karim2026,
author = {Karim, Faheem A and Tariq, Ahmed and Fitzpatrick, Christopher B and Zhou, Lauren and Suárez-Fariñas, Mayte and Schotland, Helena and Rogers, Linda and Lee, Yoon Jae and Yeo, Woon-Hong and Kim, Yun Soung},
title = {Low-Effort Respiratory Function Estimation with a Soft Wearable Digital Spirometry Patch},
journal = {Biosensors},
year = {2026},
volume = {16},
number = {5},
pages = {272},
doi = {10.3390/bios16050272}
}
EUVIMED