Recent Advances in Electrochemical Detection of Antibiotics on Graphene-Based Sensors and Biosensors, Impact and Sustainable Development Challenges: A Systematic Review and Meta-Analysis

Muhammad Saqib iD, Mrinal Vashisth iD, Elena I Korotkova iD, Amrit L Hui, Stephen O Aremu iD, Souvik Das, Aniruddha Deb iD, Nirmal K Hazra, Rachita Saha, Subrata Saha, Pradip Kumar Kar iD

Biosensors · 23.04.2026 · 16 (5) · 234

DOI: 10.3390/bios16050234 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Biosensors, online erschienen am 23.04.2026. Verfasst von Muhammad Saqib und 10 weiteren Autor:innen. Beteiligte Einrichtung: Chemical Engineering Division, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, 30 Lenin Avenue, 634050 Toms…. Hauptthemen laut MEDLINE: Anti-Bacterial Agents, Biosensing Techniques, Electrochemical Techniques, Graphite. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 159 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing use of antibiotics around the globe has contributed to an increase in antimicrobial resistance and become a major risk to both public health and sustainable development. Reliable and fast detection of antibiotic residues in clinical, agricultural, and environmental matrices is required to monitor antimicrobial resistance effectively. The conventional analytical techniques are sensitive, but they are also expensive, complex and lacking in portability. Voltammetry is a recently emerging electrochemical detection technique that is low-cost and rapid. To the best of our knowledge, for the first time, a meta-analysis was conducted on graphene-based electrochemical sensors and biosensors for antibiotic detection over the last decade. This systematic review critically examines the analytical properties of sensors and biosensors, the physicochemical properties of antibiotics, adsorption characteristics, and the use of nanoparticles to improve the selectivity and sensitivity of devices. This review critically examines the cost-effectiveness, scalability, and practicality of point-of-use devices using graphene-based sensors and biosensors. This systematic review also discusses the potential risks to human health from antibiotic contamination and the role of monitoring in contributing to achieving the UN’s Sustainable Development Goals. This systematic review identifies a gap between developing sensors in laboratories versus their deployment as field-deployable devices; it highlights challenges associated with stability, matrix effects and the complexity of manufacturing devices. Finally, it provides recommendations for future research that may help to address this gap to promote the transition of innovative devices from academic to practical applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anti-Bacterial AgentsBiosensing TechniquesElectrochemical TechniquesGraphiteHumansSustainable Development

Stichwörter der Autor:innen

antibioticantimicrobial resistance monitoringelectrochemical methodenvironmental biosensorgraphene oxidepoint-of-care diagnosticsreduced graphene oxidesensorssustainable development goalssystematic review

Substanzen

Anti-Bacterial AgentsGraphite

Autor:innen und Institutionen

  • Chemical Engineering Division, School of Earth Sciences and Engineering, National Research Tomsk Polytechnic University, 30 Lenin Avenue, 634050 Tomsk, Russia.
  • UNESCO Laboratory of Environmental Electrochemistry, Department of Analytical Chemistry, Faculty of Science, Charles University, Hlavova 8/2030, CZ 128 43 Prague 2, Czech Republic.
  • Higher Engineering School of Agrobiotech, National Research Tomsk State University, 36 Lenin Avenue, 634050 Tomsk, Russia.
  • National Research Tomsk State University, 36 Lenin Avenue, 634050 Tomsk, Russia.
  • Faculty of General Medicine, Siberian State Medical University, 634050 Tomsk, Russia.
  • Department of Industrial Design, National Institute of Technology Rourkela, Sundargarh 769008, India.

ORCID-Profile: Muhammad Saqib, Mrinal Vashisth, Elena I Korotkova, Stephen O Aremu, Aniruddha Deb, Pradip Kumar Kar

Zitieren

APA

Saqib, M., Vashisth, M., Korotkova, E. I., Hui, A. L., Aremu, S. O., Das, S., Deb, A., Hazra, N. K., Saha, R., Saha, S., & Kar, P. K. (2026). Recent Advances in Electrochemical Detection of Antibiotics on Graphene-Based Sensors and Biosensors, Impact and Sustainable Development Challenges: A Systematic Review and Meta-Analysis. Biosensors, 16(5), 234. https://doi.org/10.3390/bios16050234

Vancouver

Saqib M, Vashisth M, Korotkova EI, Hui AL, Aremu SO, Das S, et al. Recent Advances in Electrochemical Detection of Antibiotics on Graphene-Based Sensors and Biosensors, Impact and Sustainable Development Challenges: A Systematic Review and Meta-Analysis. Biosensors. 2026;16(5):234. doi:10.3390/bios16050234

BibTeX
@article{Saqib2026,
  author = {Saqib, Muhammad and Vashisth, Mrinal and Korotkova, Elena I and Hui, Amrit L and Aremu, Stephen O and Das, Souvik and Deb, Aniruddha and Hazra, Nirmal K and Saha, Rachita and Saha, Subrata and Kar, Pradip Kumar},
  title = {Recent Advances in Electrochemical Detection of Antibiotics on Graphene-Based Sensors and Biosensors, Impact and Sustainable Development Challenges: A Systematic Review and Meta-Analysis},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {5},
  pages = {234},
  doi = {10.3390/bios16050234}
}