Multimodal Phase-Space Dynamics Fusion for Robust Ischemia Screening: An Edge-AI Paradigm with SERF Magnetocardiography
Biosensors · 2026
DOI: 10.3390/bios16040228 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Keyi Li und 10 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, …. Hauptthemen laut MEDLINE: Magnetocardiography, Myocardial Ischemia. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Innovation Program for Quantum Science and Technology.
Abstract (Originalsprache)
Background
Myocardial ischemia (MI) is a major cause of morbidity and mortality worldwide and requires timely and reliable detection. Although Spin-Exchange Relaxation-Free (SERF) magnetocardiography (MCG) provides femtotesla-level sensitivity for identifying non-linear cardiac repolarization anomalies, its clinical deployment is currently impeded by the computational bottlenecks inherent to portable edge platforms.
Methods
We propose a “Sensor-to-Image” Edge-AI framework that links quantum sensing with computer vision. Single-channel SERF-MCG signals from a large cohort of 2118 subjects (1135 Healthy, 983 Ischemia) were transformed into phase-space images using three distinct encoding modalities: Recurrence Plots (RP), Gramian Angular Summation Fields (GASF), and Markov Transition Fields (MTF). These visual representations were subsequently analyzed by a streamlined MobileNetV3-Small architecture, optimized for low-latency inference. To maximize diagnostic precision, an adaptive weighted fusion mechanism was engineered to combine the chaotic specificity captured by RP with the morphological sensitivity of GASF through a validation-optimized fixed global weighting strategy.
Results
In our experiments, the fusion model achieved an Area Under the Curve (AUC) of 0.865, which was higher than the 1D-CNN baseline (AUC 0.857) and the single-modality models. Notably, the fusion strategy significantly elevated sensitivity to 88.3% while maintaining a specificity of 66.5%. Although specificity is moderate, this trade-off prioritizes high sensitivity to minimize false negatives in pre-hospital screening scenarios. The average inference time was 4.7 ms per sample on a standard CPU, suggesting suitability for real-time Point-of-Care (PoC) scenarios under further on-device validation.
Conclusions
The results suggest that multi-view phase-space fusion can capture subtle spatio-temporal changes associated with ischemia. The proposed lightweight framework may support the development of portable SERF-MCG systems with embedded AI screening.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China.
- Zhejiang Provincial Key Laboratory of Ultra-Weak Magnetic-Field Space and Applied Technology, Hangzhou Innovation Institute, Beihang University, Hangzhou 310051, China.
- Hefei National Laboratory, Hefei 230088, China.
- Department of Emergency Medicine, Qilu Hospital of Shandong University, Jinan 250012, China.
- Shandong Key Laboratory for Magnetic Field-Free Medicine & Functional Imaging, Qilu Hospital of Shandong University, Jinan 250012, China.
- Shandong Provincial Clinical Research Center for Emergency and Critical Care Medicine, Qilu Hospital of Shandong University, Jinan 250012, China.
ORCID-Profile: Keyi Li, Xiangyang Zhou, Yifan Jia, Dong Xu, Min Xiang
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Innovation Program for Quantum Science and Technology
- Fundamental and Interdisciplinary Disciplines Breakthrough Plan of the Ministry of Education of China
- Central Government Guided Local Science and Technology Development Fund Projects
- Fundamental Research Funds for the Central Universities
- Zhejiang Provincial Natural Science Foundation Exploration Project
- China National Postdoctoral Program for Innovative Talents
Zitieren
APA
Li, K., Zhou, X., Jia, Y., Wang, R., Cao, Y., Pang, J., Shang, R., Zhang, Y., Cui, Y., Xu, D., & Xiang, M. (2026). Multimodal Phase-Space Dynamics Fusion for Robust Ischemia Screening: An Edge-AI Paradigm with SERF Magnetocardiography. Biosensors. https://doi.org/10.3390/bios16040228
Vancouver
Li K, Zhou X, Jia Y, Wang R, Cao Y, Pang J, et al. Multimodal Phase-Space Dynamics Fusion for Robust Ischemia Screening: An Edge-AI Paradigm with SERF Magnetocardiography. Biosensors. 2026. doi:10.3390/bios16040228