Kurz gefasst

Vergleichsstudie in der Zeitschrift Biosensors, online erschienen am 28.03.2026. Verfasst von Maciej Polak und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sera and Vaccines Evaluation, National Institute of Public Health NIH-National Research Institute, 00-791 Warsaw, Poland. Hauptthemen laut MEDLINE: Biosensing Techniques, SARS-CoV-2, Point-of-Care Systems, Nucleic Acids. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medical Research Agency, NIPH NIH-NRI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The translation of nucleic acid amplification into practical point-of-care and biosensor-integrated diagnostics is still significantly impeded by the necessity for rapid sample preparation. For this reason, a broad comparison of seven commercially available kits for DNA/RNA extraction containing their temperature-related adjustments was performed. Extracts isolated from SARS-CoV-2-positive nasopharyngeal swabs, viral stocks, as well as laboratory-prepared suspensions of clinically relevant Gram-positive and Gram-negative bacteria were evaluated by recombinase polymerase amplification (RPA) and real-time PCR. In addition, the impact of transport media for SARS-CoV-2 samples was investigated. Extraction performance varied markedly according to the kit, pathogen, sample background. For SARS-CoV-2, rapid extraction was more effective for samples collected in viral transport medium than in inactivation buffer. Across bacterial targets, performance was species dependent, highlighting substantial differences in compatibility between simplified extraction workflows and downstream amplification. Among the rapid methods tested, a simplified QuickExtract protocol (95 °C, 5 min) provided the most consistent overall results, although it did not uniformly match the reference silica-based method for all targets. In conclusion, these results demonstrate that rapid nucleic acid extraction must be thoroughly evaluated as an essential element of the entire sample-to-answer workflow, rather than being chosen as a standalone preprocessing step for point-of-care molecular diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesSARS-CoV-2Point-of-Care SystemsNucleic AcidsCOVID-19HumansNucleic Acid Amplification TechniquesRapid Diagnostic TestsRNA, Viral

Stichwörter der Autor:innen

nucleic acid amplification (NAA) methodsrapid point-of-care (POC) diagnostic testsrecombinase polymerase amplification (RPA)

Substanzen

Nucleic AcidsRNA, Viral

Autor:innen und Institutionen

  • Department of Sera and Vaccines Evaluation, National Institute of Public Health NIH-National Research Institute, 00-791 Warsaw, Poland.
  • Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, 00-664 Warsaw, Poland.
  • Department of Infectious and Invasive Diseases and Veterinary Administration, Institute of Veterinary Medicine, Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University, 87-100 Toruń, Poland.
  • Animallab Veterinary Laboratory, 02-672 Warsaw, Poland.
  • Department of Virology, National Institute of Public Health NIH-National Research Institute, 00-791 Warsaw, Poland.

ORCID-Profile: Ewa Mosiej, Marta Prygiel, Robert Ziółkowski, Dawid Jańczak, Katarzyna Pancer, Aleksandra Anna Zasada

Förderung

  • Medical Research Agency
  • NIPH NIH-NRI

Zitieren

APA

Polak, M., Wiatrzyk, A., Krysztopa-Grzybowska, K., Sobiecka, K., Mosiej, E., Prygiel, M., Ziółkowski, R., Jańczak, D., Pancer, K., Skiba, A., & Zasada, A. A. (2026). Comparative Evaluation of Rapid Nucleic Acids Extraction Methods for Biosensor-Based Point-of-Care Solutions. Biosensors, 16(4), 195. https://doi.org/10.3390/bios16040195

Vancouver

Polak M, Wiatrzyk A, Krysztopa-Grzybowska K, Sobiecka K, Mosiej E, Prygiel M, et al. Comparative Evaluation of Rapid Nucleic Acids Extraction Methods for Biosensor-Based Point-of-Care Solutions. Biosensors. 2026;16(4):195. doi:10.3390/bios16040195

BibTeX
@article{Polak2026,
  author = {Polak, Maciej and Wiatrzyk, Aldona and Krysztopa-Grzybowska, Katarzyna and Sobiecka, Karolina and Mosiej, Ewa and Prygiel, Marta and Ziółkowski, Robert and Jańczak, Dawid and Pancer, Katarzyna and Skiba, Aleksandra and Zasada, Aleksandra Anna},
  title = {Comparative Evaluation of Rapid Nucleic Acids Extraction Methods for Biosensor-Based Point-of-Care Solutions},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {4},
  pages = {195},
  doi = {10.3390/bios16040195}
}
Kostenlos starten →