EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Surface Plasmon Resonance as a Potential Diagnostic Tool for the Detection of CXC Chemokine Receptor 4 (CXCR4) on Extracellular Vesicles

Kaat Verleye, Sam Noppen iD, Arnaud Boonen, Yagmur Yildizhan, Tom Van Loy iD, Cindy Heens, Frank Vanderhoydonc, Cláudio Pinheiro, Paula M Pincela Lins iD, Annelies Bronckaers, An Hendrix iD, Johannes V Swinnen iD und 4 weitere

Biosensors · 21.03.2026 · 16 (3) · 174

DOI: 10.3390/bios16030174 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 21.03.2026. Verfasst von Kaat Verleye und 15 weiteren Autor:innen. Beteiligte Einrichtung: Molecular, Structural and Translational Virology (Rega Institute), Department of Microbiology, Immunology and Transplantation, KU Leuven, 3000 Leuven…. Hauptthemen laut MEDLINE: Surface Plasmon Resonance, Receptors, CXCR4, Extracellular Vesicles, Biosensing Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Foundation - Flanders, Research Foundation Flanders.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study leverages surface plasmon resonance (SPR) BiacoreTM technology to unveil the diagnostic potential of detecting CXCR4 on extracellular vesicles (EVs). Despite its recognized potential as a cancer biomarker, the presence of CXCR4 on EVs remains underexplored for diagnostic purposes. Using reference material (rEVs), a standardized label-free and real-time SPR biosensor is established to molecularly profile CXCR4-positive EVs. The binding interactions between immobilized antibodies and EVs isolated from different cancer cell lines revealed a unique SPR molecular fingerprint (SPR-MFP) consisting of varying expression levels of the CD9, CD63 and CD81 EV biomarkers, as well as CXCR4. There was a strong correlation between CXCR4 expression on the cellular membrane measured by flow cytometry (FCM) and the CXCR4 SPR signal of purified EVs, indicating that the chemokine receptor is actively transferred to the extracellular space. The BiacoreTM biosensor is able to directly detect and molecularly profile EVs in buffer and spiked in cell culture supernatant supplemented with 10% EV-depleted serum. Altogether, our findings illuminate the potential of SPR BiacoreTM technology in EV-related research as well as reveal the diagnostic potential of EV-associated CXCR4, offering valuable insights and paving the way for medical applications in diseases associated with aberrant CXCR4 expression.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Surface Plasmon ResonanceReceptors, CXCR4Extracellular VesiclesBiosensing TechniquesHumansCell Line, Tumor

Stichwörter der Autor:innen

CXCR4biomarkerbiosensorextracellular vesiclessurface plasmon resonance

Substanzen

Receptors, CXCR4CXCR4 protein, human

Autor:innen und Institutionen

  • Molecular, Structural and Translational Virology (Rega Institute), Department of Microbiology, Immunology and Transplantation, KU Leuven, 3000 Leuven, Belgium.
  • Biosensors Group, Department of Biosystems, KU Leuven, 3000 Leuven, Belgium.
  • Molecular Genetics and Therapeutics in Virology and Oncology (Rega Institute), Department of Microbiology, Immunology and Transplantation, KU Leuven, 3000 Leuven, Belgium.
  • Laboratory of Lipid Metabolism and Cancer, Department of Oncology, KU Leuven, 3000 Leuven, Belgium.
  • Laboratory of Experimental Cancer Research, Department of Human Structure and Repair, Ghent University, 9000 Ghent, Belgium.
  • Department of Cardio and Organ Systems (COS), Biomedical Research Institute, Hasselt University, 3590 Diepenbeek, Belgium.

ORCID-Profile: Sam Noppen, Tom Van Loy, Paula M Pincela Lins, An Hendrix, Johannes V Swinnen, Dragana Spasic, Jeroen Lammertyn, Christophe Pannecouque, Dominique Schols

Förderung

  • Research Foundation - Flanders
  • Research Foundation Flanders

Zitieren

APA

Verleye, K., Noppen, S., Boonen, A., Yildizhan, Y., Van Loy, T., Heens, C., Vanderhoydonc, F., Pinheiro, C., Lins, P. M. P., Bronckaers, A., Hendrix, A., Swinnen, J. V., Spasic, D., Lammertyn, J., Pannecouque, C., & Schols, D. (2026). Surface Plasmon Resonance as a Potential Diagnostic Tool for the Detection of CXC Chemokine Receptor 4 (CXCR4) on Extracellular Vesicles. Biosensors, 16(3), 174. https://doi.org/10.3390/bios16030174

Vancouver

Verleye K, Noppen S, Boonen A, Yildizhan Y, Van Loy T, Heens C, et al. Surface Plasmon Resonance as a Potential Diagnostic Tool for the Detection of CXC Chemokine Receptor 4 (CXCR4) on Extracellular Vesicles. Biosensors. 2026;16(3):174. doi:10.3390/bios16030174

BibTeX
@article{Verleye2026,
  author = {Verleye, Kaat and Noppen, Sam and Boonen, Arnaud and Yildizhan, Yagmur and Van Loy, Tom and Heens, Cindy and Vanderhoydonc, Frank and Pinheiro, Cláudio and Lins, Paula M Pincela and Bronckaers, Annelies and Hendrix, An and Swinnen, Johannes V and Spasic, Dragana and Lammertyn, Jeroen and Pannecouque, Christophe and Schols, Dominique},
  title = {Surface Plasmon Resonance as a Potential Diagnostic Tool for the Detection of CXC Chemokine Receptor 4 (CXCR4) on Extracellular Vesicles},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {174},
  doi = {10.3390/bios16030174}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche