EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Nonlinear Feature-Based MI Detection Supported by DWT and EMD on ECG: A High-Performance Decision Support Approach

Ali Narin iD, Merve Keser iD

Biosensors · 04.03.2026 · 16 (3) · 150

DOI: 10.3390/bios16030150 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 04.03.2026. Verfasst von Ali Narin und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronics Engineering, Zonguldak Bülent Ecevit University, Zonguldak 67100, Türkiye. Hauptthemen laut MEDLINE: Electrocardiography, Myocardial Infarction. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 71 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Myocardial infarction (MI) is a life-threatening cardiovascular disorder caused by a partial or complete interruption of oxygenated blood flow to the myocardium, leading to high mortality rates if not diagnosed promptly. Although electrocardiogram (ECG) signals are widely used due to their non-invasive and low-cost nature, MI-specific abnormalities may be subtle and subject to inter-observer variability. Therefore, reliable artificial intelligence-based decision support systems are essential to enhance diagnostic classification accuracy. In this study, only the Lead II derivation from 12-lead ECG recordings of 52 healthy individuals and 148 MI patients was analyzed. To effectively characterize the non-stationary nature of ECG signals, a hybrid time–frequency feature extraction framework was employed. Five-level intrinsic mode functions and wavelet detail and approximation coefficients were obtained using Empirical Mode Decomposition and Discrete Wavelet Transform with a Daubechies-6 wavelet. From these components, 390 times, nonlinear and complexity-based features were extracted using 23 entropy-driven measures. Particle Swarm Optimization was applied to select the most discriminative feature subset, significantly enhancing classification performance. The optimized features were evaluated using Support Vector Machines, Artificial Neural Networks, k-Nearest Neighbors, and Bagged Tree classifiers. The Bagged Trees classifier achieved the best classification performance with an overall correct classification rate of 97.6%. The results demonstrate that the proposed hybrid feature representation combined with PSO-based selection provides a robust and reliable framework for MI detection, offering strong potential for clinical decision support applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectrocardiographyMyocardial InfarctionHumansWavelet AnalysisSupport Vector MachineAlgorithmsSignal Processing, Computer-AssistedArtificial IntelligenceSoft ComputingNeural Networks, Computer

Stichwörter der Autor:innen

ECGLead IIdiscrete wavelet transformintrinsic mode functionsmyocardial infarctionnon-linear featuresparticle swarm optimization

Autor:innen und Institutionen

  • Department of Electrical and Electronics Engineering, Zonguldak Bülent Ecevit University, Zonguldak 67100, Türkiye.

ORCID-Profile: Ali Narin, Merve Keser

Zitieren

APA

Narin, A., & Keser, M. (2026). Nonlinear Feature-Based MI Detection Supported by DWT and EMD on ECG: A High-Performance Decision Support Approach. Biosensors, 16(3), 150. https://doi.org/10.3390/bios16030150

Vancouver

Narin A, Keser M. Nonlinear Feature-Based MI Detection Supported by DWT and EMD on ECG: A High-Performance Decision Support Approach. Biosensors. 2026;16(3):150. doi:10.3390/bios16030150

BibTeX
@article{Narin2026,
  author = {Narin, Ali and Keser, Merve},
  title = {Nonlinear Feature-Based MI Detection Supported by DWT and EMD on ECG: A High-Performance Decision Support Approach},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {3},
  pages = {150},
  doi = {10.3390/bios16030150}
}
Kostenlos starten →