EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sensitive Detection of DJ-1 in Artificial Cerebrospinal Fluid Using a Portable GPTMS-Coordinated Gold Nanoparticle-Based Biosensor

Münteha Nur Sonuç Karaboğa

Biosensors · 2026

DOI: 10.3390/bios16030146 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Münteha Nur Sonuç Karaboğa. Beteiligte Einrichtung: Faculty of Health Sciences, Tekirdag Namik Kemal University, Tekirdag 59030, Türkiye. Hauptthemen laut MEDLINE: Electrochemical Techniques, Biosensing Techniques, Protein Deglycase DJ-1, Gold. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A highly selective and sensitive compact immunosensing strategy was developed for the determination of DJ-1, a potential biomarker of Parkinson’s disease, one of the leading neurodegenerative disorders, using a portable potentiostat. Initially, screen-printed carbon electrodes (SPCEs) were modified with gold nanoparticles (AuNPs), followed by functionalization with 4-mercapto-1-butanol (MOH). Subsequently, the AuNPs-doped and hydroxyl-functionalized electrodes were treated with 3-glycidoxypropyltrimethoxysilane (GPTMS) to facilitate immobilization of anti-DJ-1 antibodies. Immobilization steps were monitored using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) performed on a bench potentiostat, while the entire analytical performance of the developed biosensor system and its response in artificial cerebrospinal fluid (aCSF) were evaluated by monitoring cathodic current changes with a portable electrochemical reader. The resulting biorecognition element enabled the detection of DJ-1 within the concentration range of 0.001 to 0.3 ng/mL, based on cathodic current changes, achieving a limit of detection as low as 0.00059 ng/mL. Surface morphology and elemental composition alterations were characterized by scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), and energy-dispersive X-ray spectroscopy (EDX). A notable advantage of this GPTMS@AuNPs-based biosensor system is its prolonged storage stability and its capability to accurately quantify DJ-1 in artificial cerebrospinal fluid samples, with recovery rates ranging from 98.66% to 123.3%.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Electrochemical TechniquesBiosensing TechniquesProtein Deglycase DJ-1GoldMetal NanoparticlesSilanesImmunoassayHumansCerebrospinal FluidElectrodesLimit of Detection

Stichwörter der Autor:innen

DJ-1Parkinson’s diseaseglycidoxypropyltrimethoxysilanegold nanoparticlesportable biosensor

Substanzen

PARK7 protein, humanProtein Deglycase DJ-1Gold3-glycidoxypropyltrimethoxysilaneSilanes

Autor:innen und Institutionen

  • Faculty of Health Sciences, Tekirdag Namik Kemal University, Tekirdag 59030, Türkiye.

Zitieren

APA

Sonuç Karaboğa, M. N. (2026). Sensitive Detection of DJ-1 in Artificial Cerebrospinal Fluid Using a Portable GPTMS-Coordinated Gold Nanoparticle-Based Biosensor. Biosensors. https://doi.org/10.3390/bios16030146

Vancouver

Sonuç Karaboğa MN. Sensitive Detection of DJ-1 in Artificial Cerebrospinal Fluid Using a Portable GPTMS-Coordinated Gold Nanoparticle-Based Biosensor. Biosensors. 2026. doi:10.3390/bios16030146

BibTeX
@article{SonuKaraboa2026,
  author = {Sonuç Karaboğa, Münteha Nur},
  title = {Sensitive Detection of DJ-1 in Artificial Cerebrospinal Fluid Using a Portable GPTMS-Coordinated Gold Nanoparticle-Based Biosensor},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16030146}
}
Kostenlos starten →