Metallic Flexible NiTi Wire Microcrack Transducer for Label-Free Impedimetric Sensing of Escherichia coli
Biosensors · 2026
DOI: 10.3390/bios16010054 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Gizem Özlü Türk und 1 weiteren Autor:innen. Beteiligte Einrichtung: Biological and Medical Diagnostic Sensors Laboratory (BioMeD Sensors Lab.), Department of Biomedical Engineering, Faculty of Engineering, Erciyes Uni…. Hauptthemen laut MEDLINE: Biosensing Techniques, Escherichia coli, Nickel, Titanium. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Flexible biosensors offer rapid and low-cost diagnostics but are often limited by the mechanical and electrochemical instability of polymer-based designs in biological media. Here, we introduce a metallic flexible microcrack transducer that exploits the intrinsic deformability of superelastic nickel–titanium (NiTi) for label-free impedimetric detection. Mechanical bending of NiTi wires spontaneously generates martensitic-phase microcracks whose metal–gap–metal geometry forms the active transduction sites, where functional interfacial layers and captured analytes modulate the local dielectric environment and govern the impedance response. Our approach imparts a novel dielectric character to the alloy, enabling its unexplored application in the megahertz (MHz) frequency domain (0.01–10 MHz) where native NiTi is merely conductive. Functionalization with Escherichia coli (E. coli)-specific antibodies renders these microdomains biologically active. This effectively transforms the mechanically induced microcracks into tunable impedance elements driven by analyte binding. The γ-bent NiTi sensors achieved stable and quantitative detection of E. coli ATCC 25922 in sterile human urine, with a detection limit of 64 colony forming units (CFU) mL−1 within 45 min, without redox mediators, external labels, or amplification steps. This work pioneers the use of martensitic microcrack networks, mimicking self-healing behavior in a superelastic alloy as functional transduction elements, defining a new class of metallic flexible biosensors that integrate mechanical robustness, analytical reliability, and scalability for point-of-care biosensing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Biological and Medical Diagnostic Sensors Laboratory (BioMeD Sensors Lab.), Department of Biomedical Engineering, Faculty of Engineering, Erciyes University, Kayseri 38030, Türkiye.
- Biomedical Engineering Program, Graduate School of Natural and Applied Sciences, Erciyes University, Kayseri 38280, Türkiye.
- Biomedical Device Technologies Program, Department of Electronics and Automation, Ercis Vocational School, Van Yuzuncu Yil University, Van 65400, Türkiye.
ORCID-Profile: Gizem Özlü Türk, Mehmet Çağrı Soylu
Zitieren
APA
Özlü Türk, G., & Soylu, M. Ç. (2026). Metallic Flexible NiTi Wire Microcrack Transducer for Label-Free Impedimetric Sensing of Escherichia coli. Biosensors. https://doi.org/10.3390/bios16010054
Vancouver
Özlü Türk G, Soylu MÇ. Metallic Flexible NiTi Wire Microcrack Transducer for Label-Free Impedimetric Sensing of Escherichia coli. Biosensors. 2026. doi:10.3390/bios16010054
BibTeX
@article{zlTrk2026,
author = {Özlü Türk, Gizem and Soylu, Mehmet Çağrı},
title = {Metallic Flexible NiTi Wire Microcrack Transducer for Label-Free Impedimetric Sensing of Escherichia coli},
journal = {Biosensors},
year = {2026},
doi = {10.3390/bios16010054}
}
EUVIMED