Nanoliter-Fabricated Paper-Based Colorimetric Lateral Flow Strip for Urea Detection
Biosensors · 11.10.2025 · 15 (10) · 688
DOI: 10.3390/bios15100688 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 11.10.2025. Verfasst von Supatinee Kongkaew und 2 weiteren Autor:innen. Beteiligte Einrichtung: Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand. Hauptthemen laut MEDLINE: Urea, Colorimetry, Biosensing Techniques. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: a Postdoctoral Fellowship from Prince of Songkla University, Postdoctoral Fellowship from Prince of Songkla University, National Research Council of Thailand.
Abstract (Originalsprache)
A nanoliter-scale fabrication method was applied to construct a colorimetric lateral flow strip for urea detection (Urea-CLFS). The device involves two main papers: a nitrocellulose membrane (NC-Mb) for urease enzyme immobilization and chromatography paper (CH-PP) containing a phenol red indicator. Urea-CLFS is a tool for detecting urea that is based on enzyme catalysis and the change in color of phenol red when urea is present. The Urea-CLFS fabrication was made possible by the minimal amount of nanoliters used in reagent consumption. The use of small arrays of phenol red dots provides a higher response result compared to single dots applied on CH-PP. To find the most effective design, it analyzed how urease was aligned on NC-Mb horizontally and vertically. According to our findings, the vertical alignment of the urease enzyme on NC-Mb leads to a prolonged reaction time, which leads to higher product production. The optimization process included optimizing various parameters, including the layer number of phenol red on CH-PP, phenol red concentration, urease concentration, reaction time, and sample volume. Under optimal conditions, the Urea-CLFS provided a linear range of 0.25–8.0 mmol L−1 with an LOD of 0.34 mmol L−1, which is sufficient for human health diagnostics. The accuracy of the Urea-CLFS was demonstrated by the recovery of the human urine sample between 95 ± 3% and 103 ± 3% (n = 3).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Health and Applied Sciences, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand.
- Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand.
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand.
- Forensic Science Innovation and Service Center, Prince of Songkla University, Hat Yai, Songkhla 90110, Thailand.
ORCID-Profile: Supatinee Kongkaew
Förderung
- a Postdoctoral Fellowship from Prince of Songkla University
- Postdoctoral Fellowship from Prince of Songkla University
- National Research Council of Thailand
Zitieren
APA
Kongkaew, S., Cotchim, S., & Limbut, W. (2025). Nanoliter-Fabricated Paper-Based Colorimetric Lateral Flow Strip for Urea Detection. Biosensors, 15(10), 688. https://doi.org/10.3390/bios15100688
Vancouver
Kongkaew S, Cotchim S, Limbut W. Nanoliter-Fabricated Paper-Based Colorimetric Lateral Flow Strip for Urea Detection. Biosensors. 2025;15(10):688. doi:10.3390/bios15100688
BibTeX
@article{Kongkaew2025,
author = {Kongkaew, Supatinee and Cotchim, Suparat and Limbut, Warakorn},
title = {Nanoliter-Fabricated Paper-Based Colorimetric Lateral Flow Strip for Urea Detection},
journal = {Biosensors},
year = {2025},
volume = {15},
number = {10},
pages = {688},
doi = {10.3390/bios15100688}
}
EUVIMED