Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Naokata Kutsuzawa und 7 weiteren Autor:innen. Beteiligte Einrichtung: Micro/Nano Technology Center, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan. Hauptthemen laut MEDLINE: Electric Impedance, Polyethylene Terephthalates, Biosensing Techniques. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Agency for Medical Research and Development, Japan Society for the Promotion of Science, JSPS KAKENHI.
Abstract (Originalsprache)
Microphysiological systems (MPSs) have emerged as alternatives to animal testing in drug development, following the FDA Modernization Act 2.0. Double-layer channel-type MPS chips with porous membranes are widely used for modeling various organs, including the intestines, blood–brain barrier, renal tubules, and lungs. However, these chips faced challenges owing to optical interference caused by light scattering from the porous membrane, which hinders cell observation. Trans-epithelial electrical resistance (TEER) measurement offers a non-invasive method for assessing barrier integrity in these chips. However, existing electrode-integrated MPS chips for TEER measurement have non-uniform current densities, leading to compromised measurement accuracy. Additionally, chips made from polydimethylsiloxane have been associated with drug absorption issues. This study developed an electrode-integrated MPS chip for TEER measurement with a uniform current distribution and minimal drug absorption. Through a finite element method simulation, electrode patterns were optimized and incorporated into a polyethylene terephthalate (PET)-based chip. The device was fabricated by laminating PET films, porous membranes, and patterned gold electrodes. The chip’s performance was evaluated using a perfused Caco-2 intestinal model. TEER levels increased and peaked on day 5 when cells formed a monolayer, and then they decreased with the development of villi-like structures. Concurrently, capacitance increased, indicating microvilli formation. Exposure to staurosporine resulted in a dose-dependent reduction in TEER, which was validated by immunostaining, indicating a disruption of the tight junction. This study presents a TEER measurement MPS platform with a uniform current density and reduced drug absorption, thereby enhancing TEER measurement reliability. This system effectively monitors barrier integrity and drug responses, demonstrating its potential for non-animal drug-testing applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Micro/Nano Technology Center, Tokai University, Hiratsuka 259-1292, Kanagawa, Japan.
- Department of Medicine, Division of Pulmonary Medicine, Tokai University School of Medicine, Isehara 259-1143, Kanagawa, Japan.
- The Institute of Medical Sciences, Tokai University School of Medicine, Isehara 259-1143, Kanagawa, Japan.
- SCREEN Holdings Co., Ltd., Kyoto 612-8486, Kyoto, Japan.
- TOKYO OHKA KOGYO Co., Ltd., Koza 253-0114, Kanagawa, Japan.
ORCID-Profile: Naokata Kutsuzawa, Noriyuki Nakatani, Hiroshi Kimura
Förderung
- Japan Agency for Medical Research and Development
- Japan Society for the Promotion of Science
- JSPS KAKENHI
- Japanese Agency for Medical Research and Development
- Tokai University Imaging Center for Advanced Research
Zitieren
APA
Kutsuzawa, N., Nakamura, H., Chen, L., Fujioka, R., Mori, S., Nakatani, N., Yoshioka, T., & Kimura, H. (2025). Double-Layered Microphysiological System Made of Polyethylene Terephthalate with Trans-Epithelial Electrical Resistance Measurement Function for Uniform Detection Sensitivity. Biosensors. https://doi.org/10.3390/bios15100663
Vancouver
Kutsuzawa N, Nakamura H, Chen L, Fujioka R, Mori S, Nakatani N, et al. Double-Layered Microphysiological System Made of Polyethylene Terephthalate with Trans-Epithelial Electrical Resistance Measurement Function for Uniform Detection Sensitivity. Biosensors. 2025. doi:10.3390/bios15100663
BibTeX
@article{Kutsuzawa2025,
author = {Kutsuzawa, Naokata and Nakamura, Hiroko and Chen, Laner and Fujioka, Ryota and Mori, Shuntaro and Nakatani, Noriyuki and Yoshioka, Takahiro and Kimura, Hiroshi},
title = {Double-Layered Microphysiological System Made of Polyethylene Terephthalate with Trans-Epithelial Electrical Resistance Measurement Function for Uniform Detection Sensitivity},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15100663}
}
EUVIMED