EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Duplex EIS Sensor for Salmonella Typhi and Aflatoxin B1 Detection in Soil Runoff

Kundan Kumar Mishra iD, Krupa M Thakkar, Sumana Karmakar, Vikram Narayanan Dhamu, Sriram Muthukumar iD, Shalini Prasad iD

Biosensors · 2025

DOI: 10.3390/bios15100654 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Kundan Kumar Mishra und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA. Hauptthemen laut MEDLINE: Biosensing Techniques, Aflatoxin B1, Salmonella typhi, Soil Microbiology. Die Arbeit nennt 68 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EnLiSense LLC..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring contamination in soil and food systems remains vital for ensuring environmental and public health, particularly in agriculture-intensive regions. Existing laboratory-based techniques are often time-consuming, equipment-dependent, and impractical for rapid on-site screening. In this study, we present a portable, non-faradaic electrochemical impedance-based sensing platform capable of simultaneously detecting Salmonella Typhimurium (S. Typhi) and Aflatoxin B1 in spiked soil run-off samples. The system employs ZnO-coated electrodes functionalized with crosslinker for covalent antibody immobilization, facilitating selective, label-free detection using just 5 µL of sample. The platform achieves a detection limit of 1 CFU/mL for S. Typhi over a linear range of 10–105 CFU/mL and 0.001 ng/mL for Aflatoxin B1 across a dynamic range of 0.01–40.96 ng/mL. Impedance measurements captured with a handheld potentiostat were strongly correlated with benchtop results (R2 > 0.95), validating its reliability in field settings. The duplex sensor demonstrates high precision with recovery rates above 80% and coefficient of variation below 15% in spiked samples. Furthermore, machine learning classification of safe versus contaminated samples yielded an ROC-AUC > 0.8, enhancing its decision-making capability. This duplex sensing platform offers a robust, user-friendly solution for real-time environmental and food safety surveillance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesAflatoxin B1Salmonella typhiSoil MicrobiologySoilElectric ImpedanceElectrochemical TechniquesElectrodes

Stichwörter der Autor:innen

AflatoxinSalmonellaelectrochemical impedance spectroscopyimmunosensor

Substanzen

Aflatoxin B1Soil

Autor:innen und Institutionen

  • Department of Bioengineering, University of Texas at Dallas, Richardson, TX 75080, USA.
  • EnLiSense LLC, 1813 Audubon Pondway, Allen, TX 75013, USA.

ORCID-Profile: Kundan Kumar Mishra, Sriram Muthukumar, Shalini Prasad

Förderung

  • EnLiSense LLC.

Zitieren

APA

Mishra, K. K., Thakkar, K. M., Karmakar, S., Dhamu, V. N., Muthukumar, S., & Prasad, S. (2025). Duplex EIS Sensor for Salmonella Typhi and Aflatoxin B1 Detection in Soil Runoff. Biosensors. https://doi.org/10.3390/bios15100654

Vancouver

Mishra KK, Thakkar KM, Karmakar S, Dhamu VN, Muthukumar S, Prasad S. Duplex EIS Sensor for Salmonella Typhi and Aflatoxin B1 Detection in Soil Runoff. Biosensors. 2025. doi:10.3390/bios15100654

BibTeX
@article{Mishra2025,
  author = {Mishra, Kundan Kumar and Thakkar, Krupa M and Karmakar, Sumana and Dhamu, Vikram Narayanan and Muthukumar, Sriram and Prasad, Shalini},
  title = {Duplex EIS Sensor for Salmonella Typhi and Aflatoxin B1 Detection in Soil Runoff},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15100654}
}
Kostenlos starten →