Foreign Body Reaction to Neural Implants: A Comparative Study of Polymer Toxicity and Tissue Response
Biosensors · 2025
DOI: 10.3390/bios15090599 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Biosensors, 2025. Verfasst von Ciara Makievskaya und 15 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Bioengineering and Bioinformatics, Lomonosov Moscow State University, 119192 Moscow, Russia. Hauptthemen laut MEDLINE: Foreign-Body Reaction, Polymers, Biocompatible Materials, Prostheses and Implants. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MSU Program of Development.
Abstract (Originalsprache)
This study investigated the toxicity of ten polymer materials intended for the development of invasive neural interfaces improving the treatment of neurological diseases. Most of the materials for neural implants can cause traumatization of the surrounding tissue, inflammation, and foreign body reaction. In this study, in vitro and in vivo toxicity assessment was performed for nylon 618 (NY), polycaprolactone (PCL), polyethylene glycol diacrylate (PEGDA), polydimethylsiloxane (PDMS), polyethylene terephthalate (PET), polylactide (PLA), thermoplastic polyurethane (TPU), polypropylene (PP), polyethylene terephthalate glycol (PET-G), and polyimide (PI). The biocompatibility of these ten materials was assessed based on cell adhesion, growth and cytotoxicity on neural (PC-12) and fibroblast (NRK-49F) cultures. Furthermore, brain tissue responses to the implanted phantom scaffolds were analyzed in rats. According to these measurements, PI showed the highest compatibility for both cell types. PEGDA exhibited cytotoxic effects, low cell adhesion and the strongest foreign body reaction, including fibrosis and multinucleated cell formation. The other polymers showed lower pathological responses which makes them potentially usable for neural interfacing. We conclude that PEGDA appears to be unsuitable for long-term use due to adverse tissue and cellular reactions, whereas PI, PLA, PDMS and TPU hold promise as materials for safe and effective neural interface applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Bioengineering and Bioinformatics, Lomonosov Moscow State University, 119192 Moscow, Russia.
- Institute for Artificial Intelligence, Lomonosov Moscow State University, 119992 Moscow, Russia.
- A.N. Belozersky Institute of Physico-Chemical Biology, Lomonosov Moscow State University, 119234 Moscow, Russia.
- Federal State Budgetary Institution "Centre for Strategic Planning and Management of Biomedical Health Risks", Federal Medical Biological Agency, 119121 Moscow, Russia.
- Chemistry Department, Lomonosov Moscow State University, 119234 Moscow, Russia.
- Kurnakov Institute of General and Inorganic Chemistry of the Russian Academy of Sciences, 119991 Moscow, Russia.
ORCID-Profile: Ciara Makievskaya, Anna Brezgunova, Nadezda Andrianova, Olga Gancharova, Daniil Kozlov, Egor Plotnikov
Förderung
- MSU Program of Development
Zitieren
APA
Makievskaya, C., Brezgunova, A., Andrianova, N., Kelm, E., Solovyova, M., Naumova, G., Zeinalova, A., Gancharova, O., Bushkova, T., Kozlov, D., Putlayev, V., Evdokimov, P., Petrov, A., Lebedev, M., Plotnikov, E., & Popkov, V. (2025). Foreign Body Reaction to Neural Implants: A Comparative Study of Polymer Toxicity and Tissue Response. Biosensors. https://doi.org/10.3390/bios15090599
Vancouver
Makievskaya C, Brezgunova A, Andrianova N, Kelm E, Solovyova M, Naumova G, et al. Foreign Body Reaction to Neural Implants: A Comparative Study of Polymer Toxicity and Tissue Response. Biosensors. 2025. doi:10.3390/bios15090599
BibTeX
@article{Makievskaya2025,
author = {Makievskaya, Ciara and Brezgunova, Anna and Andrianova, Nadezda and Kelm, Evgeny and Solovyova, Maria and Naumova, Gelena and Zeinalova, Alina and Gancharova, Olga and Bushkova, Tatiana and Kozlov, Daniil and Putlayev, Valery and Evdokimov, Pavel and Petrov, Alexander and Lebedev, Mikhail and Plotnikov, Egor and Popkov, Vasily},
title = {Foreign Body Reaction to Neural Implants: A Comparative Study of Polymer Toxicity and Tissue Response},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15090599}
}
EUVIMED