EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Smartphone-Compatible Colorimetric Detection of CA19-9 Using Melanin Nanoparticles and Deep Learning

Turgut Karademir iD, Gizem Kaleli-Can iD, Başak Esin Köktürk-Güzel iD

Biosensors · 2025

DOI: 10.3390/bios15080507 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Turgut Karademir und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronics Engineering, Faculty of Engineering, Izmir Demokrasi University, 35140 Izmir, Türkiye. Hauptthemen laut MEDLINE: Colorimetry, Deep Learning, Melanins, Smartphone. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Paper-based colorimetric biosensors represent a promising class of low-cost diagnostic tools that do not require external instrumentation. However, their broader applicability is limited by the environmental concerns associated with conventional metal-based nanomaterials and the subjectivity of visual interpretation. To address these challenges, this study introduces a proof-of-concept platform—using CA19-9 as a model biomarker—that integrates naturally derived melanin nanoparticles (MNPs) with machine learning-based image analysis to enable environmentally sustainable and analytically robust colorimetric quantification. Upon target binding, MNPs induce a concentration-dependent color transition from yellow to brown. This visual signal was quantified using a machine learning pipeline incorporating automated region segmentation and regression modeling. Sensor areas were segmented using three different algorithms, with the U-Net model achieving the highest accuracy (average IoU: 0.9025 ± 0.0392). Features extracted from segmented regions were used to train seven regression models, among which XGBoost performed best, yielding a Mean Absolute Percentage Error (MAPE) of 17%. Although reduced sensitivity was observed at higher analyte concentrations due to sensor saturation, the model showed strong predictive accuracy at lower concentrations, which are especially challenging for visual interpretation. This approach enables accurate, reproducible, and objective quantification of colorimetric signals, thereby offering a sustainable and scalable alternative for point-of-care diagnostic applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColorimetryDeep LearningMelaninsSmartphoneBiosensing TechniquesNanoparticlesHumans

Stichwörter der Autor:innen

U-NETYOLOv8colorimetric analysisdedectron 2image segmentationmelanin nanoparticlepaper-based analytical devices (PADs)regression models

Substanzen

Melanins

Autor:innen und Institutionen

  • Department of Electrical and Electronics Engineering, Faculty of Engineering, Izmir Demokrasi University, 35140 Izmir, Türkiye.
  • Department of Biomedical Engineering, Faculty of Engineering, Izmir Demokrasi University, 35140 Izmir, Türkiye.

ORCID-Profile: Turgut Karademir, Gizem Kaleli-Can, Başak Esin Köktürk-Güzel

Zitieren

APA

Karademir, T., Kaleli-Can, G., & Köktürk-Güzel, B. E. (2025). Smartphone-Compatible Colorimetric Detection of CA19-9 Using Melanin Nanoparticles and Deep Learning. Biosensors. https://doi.org/10.3390/bios15080507

Vancouver

Karademir T, Kaleli-Can G, Köktürk-Güzel BE. Smartphone-Compatible Colorimetric Detection of CA19-9 Using Melanin Nanoparticles and Deep Learning. Biosensors. 2025. doi:10.3390/bios15080507

BibTeX
@article{Karademir2025,
  author = {Karademir, Turgut and Kaleli-Can, Gizem and Köktürk-Güzel, Başak Esin},
  title = {Smartphone-Compatible Colorimetric Detection of CA19-9 Using Melanin Nanoparticles and Deep Learning},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15080507}
}
Kostenlos starten →