EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

3D-Printed PLA Hollow Microneedles Loaded with Chitosan Nanoparticles for Colorimetric Glucose Detection in Sweat Using Machine Learning

Anastasia Skonta iD, Myrto G Bellou iD, Haralambos Stamatis iD

Biosensors · 2025

DOI: 10.3390/bios15070461 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Anastasia Skonta und 2 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Biotechnology, Department of Biological Applications and Technologies, University of Ioannina, 45110 Ioannina, Greece. Hauptthemen laut MEDLINE: Chitosan, Sweat, Biosensing Techniques, Glucose. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biosensors play a central role in the early detection of abnormal glucose levels in individuals with diabetes; therefore, the development of less invasive systems is essential. Herein, a 3D-printed colorimetric biosensor combining microneedles and chitosan nanoparticles was developed for glucose detection in sweat using machine learning. Briefly, hollow 3D-printed polylactic acid microneedles were constructed and loaded with chitosan nanoparticles encapsulating glucose oxidase, horseradish peroxidase, and the chromogenic substrate 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid), resulting in the formation of the chitosan nanoparticle−microneedle patches. Glucose detection was performed colorimetrically by first incubating the chitosan nanoparticle−microneedle patches with glucose samples of varying concentrations and then by using photographs of the top side of each microneedle and a color recognition application on a smartphone. The Random Sample Consensus algorithm was used to train a simple linear regression model to predict glucose concentrations in unknown samples. The developed biosensor system exhibited a good linear response range toward glucose (0.025−0.375 mM), a low limit of detection (0.023 mM), a limit of quantification (0.078 mM), high specificity, and recovery rates ranging between 86–112%. Lastly, the biosensor was applied to glucose detection in spiked artificial sweat samples, confirming the potential of the proposed methodology for glucose detection in real samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChitosanSweatBiosensing TechniquesGlucoseMachine LearningColorimetryNanoparticlesPrinting, Three-DimensionalHumansPolyestersNeedlesLimit of DetectionGlucose Oxidase

Stichwörter der Autor:innen

3D printingPLAchitosan nanoparticlescolorimetric biosensorglucoseglucose oxidasemachine learningmicroneedles

Substanzen

ChitosanGlucosePolyesterspoly(lactide)Glucose Oxidase

Autor:innen und Institutionen

  • Laboratory of Biotechnology, Department of Biological Applications and Technologies, University of Ioannina, 45110 Ioannina, Greece.

ORCID-Profile: Anastasia Skonta, Myrto G Bellou, Haralambos Stamatis

Zitieren

APA

Skonta, A., Bellou, M. G., & Stamatis, H. (2025). 3D-Printed PLA Hollow Microneedles Loaded with Chitosan Nanoparticles for Colorimetric Glucose Detection in Sweat Using Machine Learning. Biosensors. https://doi.org/10.3390/bios15070461

Vancouver

Skonta A, Bellou MG, Stamatis H. 3D-Printed PLA Hollow Microneedles Loaded with Chitosan Nanoparticles for Colorimetric Glucose Detection in Sweat Using Machine Learning. Biosensors. 2025. doi:10.3390/bios15070461

BibTeX
@article{Skonta2025,
  author = {Skonta, Anastasia and Bellou, Myrto G and Stamatis, Haralambos},
  title = {3D-Printed PLA Hollow Microneedles Loaded with Chitosan Nanoparticles for Colorimetric Glucose Detection in Sweat Using Machine Learning},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15070461}
}
Kostenlos starten →