Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity
Biosensors · 2025
DOI: 10.3390/bios15070407 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Andrea Rescalli und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, 20133 Milan, Italy. Hauptthemen laut MEDLINE: Ammonia, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fondazione UNIMI and University of Milan, Fondazione UNIMI, Italian Ministry of Research and University.
Abstract (Originalsprache)
Ammonia (NH3) detection in liquids and biological fluids is essential for monitoring environmental contamination and industrial processes, ensuring food safety, and diagnosing health conditions. Existing detection techniques are often unsuitable for point-of-care (POC) use due to limitations including complex sample handling, lack of portability, and poor compatibility with miniaturized systems. This study introduces a proof-of-concept for a compact, portable device tailored for POC detection of gaseous ammonia released from liquid samples. The device combines a polyaniline (PANI)-based chemoresistive sensor with interdigitated electrodes and a resistance readout circuit, enclosed in a gas-permeable hydrophobic membrane that permits ammonia in the vapor phase only to reach the sensing layer, ensuring selectivity and protection from liquid interference. The ink formulation was optimized. PANI nanoparticle suspension exhibited a monomodal, narrow particle size distribution with an average size of 120 nm and no evidence of larger aggregates. A key advancement of this device is its ability to limit the impact of water vapor, a known source of interference in PANI-based sensors, while maintaining a simple sensor design. A tailored signal processing strategy was implemented, extracting the slope of resistance variation over time as a robust metric for ammonia quantification. The sensor demonstrated reliable performance across a concentration range of 1.7 to 170 ppm with strong logarithmic correlation (R2 = 0.99), and very good linear correlations in low (R2 = 0.96) and high (R2 = 0.97) subranges. These findings validate the feasibility of this POC platform for sensitive, selective, and practical ammonia detection in clinical and environmental applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, Materials and Chemical Engineering "G. Natta", Politecnico di Milano, 20133 Milan, Italy.
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, 20133 Milan, Italy.
- Department of Industrial and Information Engineering, Università degli Studi di Pavia, 27100 Pavia, Italy.
ORCID-Profile: Andrea Rescalli, Ilaria Porello, Pietro Cerveri, Francesco Cellesi
Förderung
- Fondazione UNIMI and University of Milan
- Fondazione UNIMI
- Italian Ministry of Research and University
Zitieren
APA
Rescalli, A., Porello, I., Cerveri, P., & Cellesi, F. (2025). Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity. Biosensors. https://doi.org/10.3390/bios15070407
Vancouver
Rescalli A, Porello I, Cerveri P, Cellesi F. Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity. Biosensors. 2025. doi:10.3390/bios15070407
BibTeX
@article{Rescalli2025,
author = {Rescalli, Andrea and Porello, Ilaria and Cerveri, Pietro and Cellesi, Francesco},
title = {Gaseous Ammonia Sensing from Liquids via a Portable Chemosensor with Signal Correction for Humidity},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15070407}
}