MyμAlbumin: A Cutting-Edge Immunoturbidity-Based Device with Real-Time and Seamless Data Transmission for Early Detection of Chronic Kidney Disease at the Point of Care

Wanna Chaijaroenkul, Napaporn Youngvises, Artitaya Thiengsusuk, Tullayakorn Plengsuriyakarn, Jakkrapong Suwanboriboon, Kridsada Sirisabhabhorn, Wanchai Meesiri, Kesara Na-Bangchang

Biosensors · 2025

DOI: 10.3390/bios15060391 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Wanna Chaijaroenkul und 7 weiteren Autor:innen. Beteiligte Einrichtung: Graduate Program in Bioclinical Sciences, Chulabhorn International College of Medicine, Thammasat University, Pathum Thani 12120, Thailand. Hauptthemen laut MEDLINE: Renal Insufficiency, Chronic, Point-of-Care Systems, Albuminuria, Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Chulabhorn International College of Medicine, Thammasat University, National Research Council of Thailand (NRCT).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microalbuminemia, characterized by a urinary albumin concentration between 20 and 200 mg/L, is a critical marker in assessing the risk of chronic kidney disease (CKD), diabetic nephropathy, and various other chronic conditions. Previously, we developed and validated the MyACR point-of-care (PoC) device, which facilitates the monitoring of CKD progression through real-time data transmission, thus enhancing patient management. This device utilizes a spectrophotometric dye-binding assay to measure albumin and creatinine concentrations in urine samples, providing an albumin-to-creatinine ratio (ACR) result. In the present study, we introduced a refined version of the PoC device, MyμAlbumin, designed to offer a simple, accurate, specific, sensitive, and rapid method for detecting microalbumin in urine as an early indicator of CKD and related diseases. The measurement is based on a specific immunoturbidimetric assay in a microcuvette, using a total solution volume of 125 µL (n = 5 for each validation test). The MyμAlbumin device demonstrated excellent performance, achieving high accuracy (%DMV ≤ 4.67) and precision (%CV < 5) and a strong correlation (R2 > 0.995) with laboratory spectrophotometry (dye-binding assay) and reference hospital-based immunoturbidimetric assay. Its high sensitivity (LOQ = 5 mg/L) positions MyμAlbumin as a highly viable and cost-effective tool for clinical use. Additionally, the device supports real-time, seamless data transmission, making it ideal for integration into remote healthcare settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal Insufficiency, ChronicPoint-of-Care SystemsAlbuminuriaBiosensing TechniquesHumansEarly DiagnosisCreatinineNephelometry and Turbidimetry

Stichwörter der Autor:innen

chronic kidney diseasemicroalbuminpoint-of-care (PoC) medical device

Substanzen

Creatinine

Autor:innen und Institutionen

  • Graduate Program in Bioclinical Sciences, Chulabhorn International College of Medicine, Thammasat University, Pathum Thani 12120, Thailand.
  • Drug Discovery and Development Center, Office of Advanced Science and Technology, Thammasat University, Pathum Thani 12120, Thailand.
  • Bangkok High Lab Co., Ltd., Bang Khen District, Bangkok 10220, Thailand.
  • Department of Medical Technology Laboratory, Thammasat University Hospital, Pathum Thani 12120, Thailand.

Förderung

  • Chulabhorn International College of Medicine, Thammasat University
  • National Research Council of Thailand (NRCT)

Zitieren

APA

Chaijaroenkul, W., Youngvises, N., Thiengsusuk, A., Plengsuriyakarn, T., Suwanboriboon, J., Sirisabhabhorn, K., Meesiri, W., & Na-Bangchang, K. (2025). MyμAlbumin: A Cutting-Edge Immunoturbidity-Based Device with Real-Time and Seamless Data Transmission for Early Detection of Chronic Kidney Disease at the Point of Care. Biosensors. https://doi.org/10.3390/bios15060391

Vancouver

Chaijaroenkul W, Youngvises N, Thiengsusuk A, Plengsuriyakarn T, Suwanboriboon J, Sirisabhabhorn K, et al. MyμAlbumin: A Cutting-Edge Immunoturbidity-Based Device with Real-Time and Seamless Data Transmission for Early Detection of Chronic Kidney Disease at the Point of Care. Biosensors. 2025. doi:10.3390/bios15060391

BibTeX
@article{Chaijaroenkul2025,
  author = {Chaijaroenkul, Wanna and Youngvises, Napaporn and Thiengsusuk, Artitaya and Plengsuriyakarn, Tullayakorn and Suwanboriboon, Jakkrapong and Sirisabhabhorn, Kridsada and Meesiri, Wanchai and Na-Bangchang, Kesara},
  title = {MyμAlbumin: A Cutting-Edge Immunoturbidity-Based Device with Real-Time and Seamless Data Transmission for Early Detection of Chronic Kidney Disease at the Point of Care},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15060391}
}
Kostenlos starten →