EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Assessing the Role of EEG Biosignal Preprocessing to Enhance Multiscale Fuzzy Entropy in Alzheimer’s Disease Detection

Pasquale Arpaia iD, Maria Cacciapuoti iD, Andrea Cataldo iD, Sabatina Criscuolo iD, Egidio De Benedetto iD, Antonio Masciullo iD, Marisa Pesola iD, Raissa Schiavoni iD

Biosensors · 10.06.2025 · 15 (6) · 374

DOI: 10.3390/bios15060374 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 10.06.2025. Verfasst von Pasquale Arpaia und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Information Technology and Electrical Engineering, University of Naples Federico II, 80125 Naples, Italy. Hauptthemen laut MEDLINE: Alzheimer Disease, Electroencephalography, Signal Processing, Computer-Assisted. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Italian Ministry of Enterpise and Made in Italy, Italian Ministry of University and Research, Italian Ministry of Enterpise and Made in Italy (MIMIT) through the “INTENSE—INtegrated Technologies and ENhanced SEnsing for cognition and rehabilitation” pro….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative electroencephalography (QEEG) has emerged as a promising tool for detecting Alzheimer’s disease (AD). Among QEEG measures, Multiscale Fuzzy Entropy (MFE) shows great potential in identifying AD-related changes in EEG complexity. However, MFE is intrinsically linked to signal amplitude, which can vary substantially among EEG systems, and this hinders the adoption of this metric for AD detection. To overcome this issue, this study investigates different preprocessing strategies to make the calculation of MFE less dependent on the specific amplitude characteristics of the EEG signals at hand. This contributes to generalizing and making more robust the adoption of MFE for AD detection. To demonstrate the robustness of the proposed preprocessing methods, binary classification tasks with Support Vector Machines (SVMs), Random Forest (RF), and K-Nearest Neighbor (KNN) classifiers are used. Performance metrics, such as classification accuracy and Matthews Correlation Coefficient (MCC), are employed to assess the results. The methodology is validated on two public EEG datasets. Results show that amplitude transformation, particularly normalization, significantly enhances AD detection, achieving mean classification accuracy values exceeding 80% with an uncertainty of 10% across all classifiers. These results highlight the importance of preprocessing in improving the accuracy and the reliability of EEG-based AD diagnostic tools, offering potential advancements in patient management and treatment planning.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Alzheimer DiseaseElectroencephalographySignal Processing, Computer-AssistedHumansEntropyFuzzy LogicSupport Vector MachineAlgorithms

Stichwörter der Autor:innen

Alzheimer’s diseasebioimagingcomplexityelectroencephalographyhealth monitoringmultiscale fuzzy entropysignal processing

Autor:innen und Institutionen

  • Department of Information Technology and Electrical Engineering, University of Naples Federico II, 80125 Naples, Italy.
  • Institute of Intelligent Industrial Technologies and Systems for Advanced Manufacturing, National Research Council of Italy, 20133 Milan, Italy.
  • Department of Engineering for Innovation, University of Salento, 73100 Lecce, Italy.

ORCID-Profile: Pasquale Arpaia, Maria Cacciapuoti, Andrea Cataldo, Sabatina Criscuolo, Egidio De Benedetto, Antonio Masciullo, Marisa Pesola, Raissa Schiavoni

Förderung

  • Italian Ministry of Enterpise and Made in Italy
  • Italian Ministry of University and Research
  • Italian Ministry of Enterpise and Made in Italy (MIMIT) through the “INTENSE—INtegrated Technologies and ENhanced SEnsing for cognition and rehabilitation” pro…
  • PNRR DM

Zitieren

APA

Arpaia, P., Cacciapuoti, M., Cataldo, A., Criscuolo, S., De Benedetto, E., Masciullo, A., Pesola, M., & Schiavoni, R. (2025). Assessing the Role of EEG Biosignal Preprocessing to Enhance Multiscale Fuzzy Entropy in Alzheimer’s Disease Detection. Biosensors, 15(6), 374. https://doi.org/10.3390/bios15060374

Vancouver

Arpaia P, Cacciapuoti M, Cataldo A, Criscuolo S, De Benedetto E, Masciullo A, et al. Assessing the Role of EEG Biosignal Preprocessing to Enhance Multiscale Fuzzy Entropy in Alzheimer’s Disease Detection. Biosensors. 2025;15(6):374. doi:10.3390/bios15060374

BibTeX
@article{Arpaia2025,
  author = {Arpaia, Pasquale and Cacciapuoti, Maria and Cataldo, Andrea and Criscuolo, Sabatina and De Benedetto, Egidio and Masciullo, Antonio and Pesola, Marisa and Schiavoni, Raissa},
  title = {Assessing the Role of EEG Biosignal Preprocessing to Enhance Multiscale Fuzzy Entropy in Alzheimer’s Disease Detection},
  journal = {Biosensors},
  year = {2025},
  volume = {15},
  number = {6},
  pages = {374},
  doi = {10.3390/bios15060374}
}
Kostenlos starten →