Probing the Influence of Specular Reflection and Overexposure on Backscattering Mueller Matrix Polarimetry for Tissue Imaging and Sensing
Biosensors · 21.05.2025 · 15 (5) · 333
DOI: 10.3390/bios15050333 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 21.05.2025. Verfasst von Wei Jiao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Techno…. Hauptthemen laut MEDLINE: Liver, Biosensing Techniques. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Mueller matrix polarimetry has great potential for tissue detection and clinical diagnosis due to its ability to provide rich microstructural information accurately. However, in practical in vivo tissue imaging based on backscattering Mueller matrix polarimetry, specular reflection is often inevitable, leading to overexposed regions and the following inaccurate polarization information acquisition of tissues. In this study, we probe the influence of specular reflection and overexposure on backscattering Mueller matrix polarimetry for tissue imaging and sensing. We investigate in detail the differentiation of polarization behaviors between the specular reflection and non-specular reflection tissue regions using a 3 × 3 backscattering Mueller matrix measurement. Then, we obtain the vertical projection profiles to further quantify the Mueller matrix elements of porcine liver tissue in different specular reflection regions. Finally, we calculate the polarization feature parameters derived from a 3 × 3 Mueller matrix and analyze their behavior in overexposed regions. Based on the quantitative analysis and comparisons, we obtain a group of polarization feature parameters with strong immunity to the specular reflection process. This study offers a strategy for selecting the polarization parameters during in vivo polarimetric imaging applications, provides valuable references for further eliminating the characterization errors induced by specular reflection, and may contribute to the advancement of quantitative tissue polarimetric imaging and sensing.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Guangdong Research Center of Polarization Imaging and Measurement Engineering Technology, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Institute of Biopharmaceutical and Health Engineering, Tsinghu…
- Department of Engineering Science, University of Oxford, Parks Road, Oxford OX1 3PJ, UK.
ORCID-Profile: Wei Jiao, Nan Zeng, Rui Hao, Hui Ma, Chao He, Honghui He
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Jiao, W., Zeng, N., Hao, R., Ma, H., He, C., & He, H. (2025). Probing the Influence of Specular Reflection and Overexposure on Backscattering Mueller Matrix Polarimetry for Tissue Imaging and Sensing. Biosensors, 15(5), 333. https://doi.org/10.3390/bios15050333
Vancouver
Jiao W, Zeng N, Hao R, Ma H, He C, He H. Probing the Influence of Specular Reflection and Overexposure on Backscattering Mueller Matrix Polarimetry for Tissue Imaging and Sensing. Biosensors. 2025;15(5):333. doi:10.3390/bios15050333
BibTeX
@article{Jiao2025,
author = {Jiao, Wei and Zeng, Nan and Hao, Rui and Ma, Hui and He, Chao and He, Honghui},
title = {Probing the Influence of Specular Reflection and Overexposure on Backscattering Mueller Matrix Polarimetry for Tissue Imaging and Sensing},
journal = {Biosensors},
year = {2025},
volume = {15},
number = {5},
pages = {333},
doi = {10.3390/bios15050333}
}
EUVIMED