EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

One-Pot Detection of miRNA by Dual Rolling Circle Amplification at Ambient Temperature with High Specificity and Sensitivity

Wenhua Sun, Kunling Hu, Ziting Song, Ran An iD, Xingguo Liang iD

Biosensors · 15.05.2025 · 15 (5) · 317

DOI: 10.3390/bios15050317 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 15.05.2025. Verfasst von Wenhua Sun und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Marine Food Processing & Safety Control, College of Food Science and Engineering, Ocean University of China, No. 1299 Sansha …. Hauptthemen laut MEDLINE: MicroRNAs, Nucleic Acid Amplification Techniques, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Natural Science Foundation of China, the Open Foundation of State Key Laboratory of Marine Food Processing & Safety Control, Youth Innovation Team Program of Universities in Shandong Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rolling circle amplification (RCA) at ambient temperature is prone to false positive signals during nucleic acid detection, which makes it challenging to establish an efficient RCA detection method. The false positive signals are primarily caused by binding of non-target nucleic acids to the circular single-stranded template, leading to non-specific amplification. Here, we present an RCA method for miRNA detection at 37 °C using two circular ssDNAs, each of which is formed by ligating the intramolecularly formed nick (without any splint) in a secondary structure. The specific target recognition is realized by utilizing low concentrations (0.1 nM) of circular ssDNA1 (C1). A phosphorothioate modification is present at G*AATTC on C1 to generate a nick for primer extension during the primer self-generated rolling circle amplification (PG-RCA). The fragmented amplification products are used as primers for the following RCA that serves as signal amplification using circular ssDNA2 (C2). Notably, the absence of splints and the low concentration of C1 significantly inhibits non-target binding, thus minimizing false positive signals. A high concentration (10 nM) of C2 is used to carry out linear rolling circle amplification (LRCA), which is highly specific. This strategy demonstrates a good linear response to 0.01–100 pM of miRNA with a detection limit of 7.76 fM (miR-155). Moreover, it can distinguish single-nucleotide mismatch in the target miRNA, enabling the rapid one-pot detection of miRNA at 37 °C. Accordingly, this method performs with high specificity and sensitivity. This approach is suitable for clinical serum sample analysis and offers a strategy for developing specific biosensors and diagnostic tools.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicroRNAsNucleic Acid Amplification TechniquesBiosensing TechniquesTemperatureHumansDNA, Single-StrandedLimit of DetectionSensitivity and Specificity

Stichwörter der Autor:innen

circular ssDNAdual RCAmicroRNA detectionsplintssDNA circularization

Substanzen

MicroRNAsDNA, Single-Stranded

Autor:innen und Institutionen

  • State Key Laboratory of Marine Food Processing & Safety Control, College of Food Science and Engineering, Ocean University of China, No. 1299 Sansha Road, Qingdao 266404, China.
  • Laboratory for Marine Drugs and Bioproducts, Qingdao Marine Science and Technology Center, No. 1 Wenhai Road, Qingdao 266237, China.

ORCID-Profile: Ran An, Xingguo Liang

Förderung

  • the National Natural Science Foundation of China
  • the Open Foundation of State Key Laboratory of Marine Food Processing & Safety Control
  • Youth Innovation Team Program of Universities in Shandong Province
  • National Natural Science Foundation of China
  • Open Foundation of State Key Laboratory of Marine Food Processing and Safety Control

Zitieren

APA

Sun, W., Hu, K., Song, Z., An, R., & Liang, X. (2025). One-Pot Detection of miRNA by Dual Rolling Circle Amplification at Ambient Temperature with High Specificity and Sensitivity. Biosensors, 15(5), 317. https://doi.org/10.3390/bios15050317

Vancouver

Sun W, Hu K, Song Z, An R, Liang X. One-Pot Detection of miRNA by Dual Rolling Circle Amplification at Ambient Temperature with High Specificity and Sensitivity. Biosensors. 2025;15(5):317. doi:10.3390/bios15050317

BibTeX
@article{Sun2025,
  author = {Sun, Wenhua and Hu, Kunling and Song, Ziting and An, Ran and Liang, Xingguo},
  title = {One-Pot Detection of miRNA by Dual Rolling Circle Amplification at Ambient Temperature with High Specificity and Sensitivity},
  journal = {Biosensors},
  year = {2025},
  volume = {15},
  number = {5},
  pages = {317},
  doi = {10.3390/bios15050317}
}
Kostenlos starten →