EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Ultrasensitive Bead-Based Immunoassay for Real-Time Continuous Sample Flow Analysis

Yuri M Shlyapnikov, Elena A Shlyapnikova

Biosensors · 2025

DOI: 10.3390/bios15050316 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Yuri M Shlyapnikov und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, Institutskaya 3, 142290 Pushchino, Russia. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Ministry of Education and Science, Russia, framework of State assignment.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The performance of heterophase immunoassays is often limited by the kinetics of analyte binding. This problem is partially solved by bead-based assays, which are characterized by rapid diffusion in the particle suspension. However, at low analyte concentrations, the binding rate is still low. Here, we demonstrate a further improvement of analyte binding kinetics in bead-based immunoassays by simultaneously concentrating both an analyte and magnetic beads in a compact spatial region where binding occurs. The analyte is electrophoretically concentrated in a flow cell where beads are magnetically retained and dragged along the channel by viscous force. The flow cell is integrated with a microarray-based signal detection module, where beads with bound analyte scan the microarray surface and are retained on it by single specific interactions, assuring ultra-high sensitivity of the method. Thus, a continuous flow assay system is formed. Its performance is demonstrated by simultaneous detection of model pathogen biomarkers, cholera toxin (CT) and staphylococcal enterotoxin B (SEB), with a detection limit of 0.1 fM and response time of under 10 min. The assay is capable of real-time online sample monitoring, as shown by a 12 h long continuous flow analysis of tap water for SEB and CT.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesImmunoassayCholera ToxinEnterotoxinsLimit of Detection

Stichwörter der Autor:innen

bead-based ultrasensitive immunoassaycholera toxinmagnetic beadsstaphylococcal enterotoxin B

Substanzen

Cholera ToxinEnterotoxinsenterotoxin B, staphylococcal

Autor:innen und Institutionen

  • Institute of Theoretical and Experimental Biophysics of the Russian Academy of Sciences, Institutskaya 3, 142290 Pushchino, Russia.

Förderung

  • Ministry of Education and Science, Russia
  • framework of State assignment

Zitieren

APA

Shlyapnikov, Y. M., & Shlyapnikova, E. A. (2025). Ultrasensitive Bead-Based Immunoassay for Real-Time Continuous Sample Flow Analysis. Biosensors. https://doi.org/10.3390/bios15050316

Vancouver

Shlyapnikov YM, Shlyapnikova EA. Ultrasensitive Bead-Based Immunoassay for Real-Time Continuous Sample Flow Analysis. Biosensors. 2025. doi:10.3390/bios15050316

BibTeX
@article{Shlyapnikov2025,
  author = {Shlyapnikov, Yuri M and Shlyapnikova, Elena A},
  title = {Ultrasensitive Bead-Based Immunoassay for Real-Time Continuous Sample Flow Analysis},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15050316}
}
Kostenlos starten →