EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improving the Accuracy of a Wearable Uroflowmeter for Incontinence Monitoring Under Dynamic Conditions: Leveraging Machine Learning Methods

Faezeh Shanehsazzadeh iD, John O L DeLancey iD, James A Ashton-Miller iD

Biosensors · 2025

DOI: 10.3390/bios15050306 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Faezeh Shanehsazzadeh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA. Hauptthemen laut MEDLINE: Machine Learning, Wearable Electronic Devices, Urinary Incontinence, Flowmeters. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIA NIH HHS, NIDDK NIH HHS, U.S. Public Health Service.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Urinary incontinence affects many women, yet there are no monitoring devices capable of accurately capturing flow dynamics during everyday activities. Building on our initial development of a wearable personal uroflowmeter, this study enhances the device’s performance under realistic, dynamic conditions similar to those encountered in daily living. We integrated an optimized eight-vane Etoile flow conditioner with a 0.2D opening into the device. Both computational fluid dynamics simulations and experimental tests demonstrated that this flow conditioner significantly reduced turbulence intensity by 82% and stabilized the axial velocity profile by 67%, increasing the R2 of flow rate measurements from 0.44 to 0.92. Furthermore, our machine learning framework—utilizing a support vector machine (SVM) and an extreme gradient boosting (XGBoost) model with principal component analysis (PCA)—accurately predicted the true flow rate with high correlations, robust performance, and minimal overfitting. For the test dataset, the SVM achieved a correlation of 0.86, an R2 of 0.74, and an MAE of 2.8, whereas the XGBoost-PCA model exhibited slightly stronger performance, with a correlation of 0.88, an R2 of 0.76, and an MAE of 2.6. These advances established a solid foundation for developing a reliable, wearable uroflowmeter capable of effectively monitoring urinary incontinence in real-world settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Machine LearningWearable Electronic DevicesUrinary IncontinenceFlowmetersHumansFemaleSupport Vector MachineMonitoring, Physiologic

Stichwörter der Autor:innen

dynamic flow conditionsextreme gradient boostingflow conditionermachine learningsupport vector machinesurinary incontinenceuroflowmeterwearable device

Autor:innen und Institutionen

  • Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109, USA.
  • Department of Obstetrics & Gynecology, University of Michigan, Ann Arbor, MI 48109, USA.

ORCID-Profile: Faezeh Shanehsazzadeh, John O L DeLancey, James A Ashton-Miller

Förderung

  • NIA NIH HHS
  • NIDDK NIH HHS
  • U.S. Public Health Service
  • Procter & Gamble
  • Procter and Gamble

Zitieren

APA

Shanehsazzadeh, F., DeLancey, J. O. L., & Ashton-Miller, J. A. (2025). Improving the Accuracy of a Wearable Uroflowmeter for Incontinence Monitoring Under Dynamic Conditions: Leveraging Machine Learning Methods. Biosensors. https://doi.org/10.3390/bios15050306

Vancouver

Shanehsazzadeh F, DeLancey JOL, Ashton-Miller JA. Improving the Accuracy of a Wearable Uroflowmeter for Incontinence Monitoring Under Dynamic Conditions: Leveraging Machine Learning Methods. Biosensors. 2025. doi:10.3390/bios15050306

BibTeX
@article{Shanehsazzadeh2025,
  author = {Shanehsazzadeh, Faezeh and DeLancey, John O L and Ashton-Miller, James A},
  title = {Improving the Accuracy of a Wearable Uroflowmeter for Incontinence Monitoring Under Dynamic Conditions: Leveraging Machine Learning Methods},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15050306}
}
Kostenlos starten →