Multi-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare
Biosensors · 2025
DOI: 10.3390/bios15050304 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von C Ferreira und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tyndall National Institute, University College Cork, Lee Maltings, T12 R5CP Cork, Ireland. Hauptthemen laut MEDLINE: Electrochemical Techniques, Biosensing Techniques, Animal Welfare. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Research Ireland and the Irish Department of Agriculture, Food, and the Marine through the VistaMilk Research Ireland Centre, Insight Research Ireland Centre for Data Analytics, European Regional Development Fund.
Abstract (Originalsprache)
The rapid growth of the dairy sector requires advanced monitoring tools to ensure sustainable practices that benefit the environment, economy, and human health. Current monitoring devices often lack multi-parametric capabilities, limiting their ability to provide comprehensive data on critical chemical and biochemical parameters. To address this challenge, this work presented the integration of a real-time multi-parametric device with sensors for pH, temperature, nitrate, and nitrite, providing a comprehensive solution to dairy cattle health monitoring. This solution included an electrochemical platform, Portable Unit for Lab-on-Site Electrochemistry (PULSE), and an application for data processing and display. In-house fabricated flexible gold-printed electrodes demonstrated accurate detection of nitrite and nitrate when integrated with the PULSE, achieving sensitivities of 6.32 μA/ppm/cm2 in artificial interstitial fluid and 1.92 μA/ppm/cm2 in phosphate buffered saline, respectively. The PULSE achieved 65.83% and 58.3% lower limits of detection in phosphate buffered saline than a benchtop potentiostat, for nitrate and nitrite, respectively, along with a 24.5% increase in nitrite sensitivity, enhancing its ability to detect lower analyte concentrations. pH sensing was carried out with a commercial screen-printed electrode coated with a layer of iridium oxide. The pH was tested in ruminal complex fluid, obtaining a pH sensitivity of −59.63 mV/pH and an accuracy of 98.9%. These findings highlighted the potential of this technology as an effective tool for dairy cattle health monitoring and its deployment in real-world scenarios.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Tyndall National Institute, University College Cork, Lee Maltings, T12 R5CP Cork, Ireland.
ORCID-Profile: C Ferreira, F Barry, L C Nagle, S R Teixeira, P Galvin
Förderung
- Research Ireland and the Irish Department of Agriculture, Food, and the Marine through the VistaMilk Research Ireland Centre
- Insight Research Ireland Centre for Data Analytics
- European Regional Development Fund
Zitieren
APA
Ferreira, C., Lynch, E., O'Herlihy, A., Barry, F., Nagle, L. C., Teixeira, S. R., & Galvin, P. (2025). Multi-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare. Biosensors. https://doi.org/10.3390/bios15050304
Vancouver
Ferreira C, Lynch E, O'Herlihy A, Barry F, Nagle LC, Teixeira SR, et al. Multi-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare. Biosensors. 2025. doi:10.3390/bios15050304
BibTeX
@article{Ferreira2025,
author = {Ferreira, C and Lynch, E and O'Herlihy, A and Barry, F and Nagle, L C and Teixeira, S R and Galvin, P},
title = {Multi-Parametric Electrochemical Sensing Platform: Applications in Animal Welfare},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15050304}
}
EUVIMED