AFM-Based Monitoring of Enzymatic Activity of Individual Molecules of Cytochrome CYP102A1
Biosensors · 2025
DOI: 10.3390/bios15050303 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Yuri D Ivanov und 6 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Biomedical Chemistry, 10, Pogodinskaya St., Moscow 119121, Russia. Hauptthemen laut MEDLINE: Microscopy, Atomic Force, Cytochrome P-450 Enzyme System, Biosensing Techniques, NADPH-Ferrihemoprotein Reductase. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The Ministry of Science and Higher Education of the Russian Federation, Ministry of Science and Higher Education of the Russian Federation.
Abstract (Originalsprache)
Herein, we report the use of a nanotechnology-based approach for the study of enzyme-functionalized mica surfaces. Atomic force microscopy (AFM) has been employed for the determination of the catalytic activity of single molecules of heme-containing cytochrome P450 CYP102A1 (CYP102A1) enzyme, which was immobilized on the surface of a mica chip. Height fluctuations in individual molecules of the enzyme were measured under near-native conditions by AFM measurements in liquid using a cantilever with a 10 to 20 nm tip curvature radius. We have found that in the process of enzymatic catalysis, the mean amplitude of height fluctuations in individual enzyme molecules is 1.4-fold higher than that of enzyme molecules in an inactive state. The temperature dependence of the mean amplitude of height fluctuations in cytochrome CYP102A1 has been revealed, and the maximum of this dependence has been observed at 22 °C. The proposed nanotechnology-based approach can be employed in studies of a wide variety of enzymes, which are important for the development of novel diagnostic tests and systems for pharmaceutical analysis. The approach developed in our work will favor further miniaturization of enzyme-based biosensors and the transition from traditional sensors to nanobiosensors.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Biomedical Chemistry, 10, Pogodinskaya St., Moscow 119121, Russia.
- Foundation of Perspective Technologies and Novations, Moscow 125315, Russia.
- Institute of Bioorganic Chemistry, National Academy of Sciences of Belarus, 220084 Minsk, Belarus.
ORCID-Profile: Yuri D Ivanov, Ivan D Shumov, Oleg N Afonin
Förderung
- The Ministry of Science and Higher Education of the Russian Federation
- Ministry of Science and Higher Education of the Russian Federation
Zitieren
APA
Ivanov, Y. D., Bukharina, N. S., Shumov, I. D., Afonin, O. N., Tatur, V. Y., Grudo, A. V., & Archakov, A. I. (2025). AFM-Based Monitoring of Enzymatic Activity of Individual Molecules of Cytochrome CYP102A1. Biosensors. https://doi.org/10.3390/bios15050303
Vancouver
Ivanov YD, Bukharina NS, Shumov ID, Afonin ON, Tatur VY, Grudo AV, et al. AFM-Based Monitoring of Enzymatic Activity of Individual Molecules of Cytochrome CYP102A1. Biosensors. 2025. doi:10.3390/bios15050303
BibTeX
@article{Ivanov2025,
author = {Ivanov, Yuri D and Bukharina, Natalia S and Shumov, Ivan D and Afonin, Oleg N and Tatur, Vadim Y and Grudo, Anna V and Archakov, Alexander I},
title = {AFM-Based Monitoring of Enzymatic Activity of Individual Molecules of Cytochrome CYP102A1},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15050303}
}
EUVIMED