EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject

Chenyan Song, Ehsan Yavari, Xiaomeng Gao, Victor M Lubecke, Olga Boric-Lubecke

Biosensors · 2025

DOI: 10.3390/bios15050273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Chenyan Song und 4 weiteren Autor:innen. Beteiligte Einrichtung: Adnoviv, Inc., Honolulu, HI 96822, USA. Hauptthemen laut MEDLINE: Radar, Respiration, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. National Science Foundation, United States Department of Energy, National Science Foundation (NSF).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Doppler radar node occupancy sensors are promising for applications in smart buildings due to their simple circuits and price advantage compared to quadrature radar sensors. However, single-channel sensitivity limitations may result in low sensitivity and misinterpreted motion rates if the detected subject is at or close to “null” points. We designed and tested a novel method to eliminate such limits, demonstrating that passive nodes can be used to detect a sedentary person regardless of position. This method is based on characteristics of chest motion due to respiration, found via both simulations and experiments based on a sinusoidal model and a more realistic model of cardiorespiratory motion. In addition, respiratory rate variability is considered to distinguish a true human presence from a mechanical target. Sensor node data were collected simultaneously with an infrared camera system, which provided a respiration signal reference, to test the algorithm with 19 human subjects and a mechanical target. The results indicate that a human presence was detected with 100% accuracy and successfully differentiated from a mechanical target in a controlled environment. The developed method can greatly improve the occupancy detection accuracy of single-channel radar-based occupancy sensors and facilitate their adoption in smart building applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadarRespirationBiosensing TechniquesHumansAlgorithmsSignal Processing, Computer-AssistedMaleAdultRespiratory Rate

Stichwörter der Autor:innen

Doppler radarcardiorespiratory motionoccupancy sensorrespiration signal

Autor:innen und Institutionen

  • Adnoviv, Inc., Honolulu, HI 96822, USA.
  • Aptiv, Inc., Carmel, IN 46032, USA.
  • Department of Electrical and Computer Engineering, University of Hawaii at Manoa, Honolulu, HI 96822, USA.

Förderung

  • U.S. National Science Foundation
  • United States Department of Energy
  • National Science Foundation (NSF)
  • Department of Energy

Zitieren

APA

Song, C., Yavari, E., Gao, X., Lubecke, V. M., & Boric-Lubecke, O. (2025). Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject. Biosensors. https://doi.org/10.3390/bios15050273

Vancouver

Song C, Yavari E, Gao X, Lubecke VM, Boric-Lubecke O. Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject. Biosensors. 2025. doi:10.3390/bios15050273

BibTeX
@article{Song2025,
  author = {Song, Chenyan and Yavari, Ehsan and Gao, Xiaomeng and Lubecke, Victor M and Boric-Lubecke, Olga},
  title = {Respiration Signal Pattern Analysis for Doppler Radar Sensor with Passive Node and Its Application in Occupancy Sensing of a Stationary Subject},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15050273}
}
Kostenlos starten →