Cascade Fluorescent Sensors Based on Isothermal Signal Amplification for the Detection of Mercury and Silver Ions
Biosensors · 2025
DOI: 10.3390/bios15040213 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Zhen Liu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Hengyang School of Medicine, University of South China, Hengyang 421001, China. Hauptthemen laut MEDLINE: Mercury, Silver, Biosensing Techniques. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: This research was supported by the Hunan Provincial Natural Science Foundation of China, the Scientific Research Project of Hunan Provincial Health Commission, Hunan Provincial Natural Science Foundation of China.
Abstract (Originalsprache)
In this study, novel fluorescent DNA biosensors for mercury (Hg2+) and silver (Ag+) ions were developed based on thymine (T)- and cytosine (C)-rich recognition elements in combination with exonuclease III and a mismatch-catalyzed hairpin assembly (MCHA)-based cascade isothermal signal-amplification strategy. In the presence of the respective target analytes, the recognition element terminals form so-called T-Hg2+-T or C-Ag+-C structures, resulting in cleavage by Exo III and the release of the trigger strand for MCHA. This binds to the H1 hairpin, which is fluorescently labeled with carboxyfluorescein (FAM) and tetramethylrhodamine (TAMRA), disrupting fluorescence resonance energy transfer between them and, thus, restoring FAM fluorescence, generating a strong signal at 520 nm. The linear range of the Hg2+ sensor is 0.5 to 3 pM, with a detection limit of 0.07 pM. The recovery range in actual spiked water samples is between 98.5% and 105.2%, with a relative standard deviation (RSD) ranging from 2.0% to 4.2%. The linear range of the Ag+ sensor is 10 to 90 pM, with a detection limit of 7.6 pM. The recovery range in actual spiked water samples is between 96.2% and 104.1%, with an RSD ranging from 3.2% to 6.3%. The cascade isothermal signal amplification strategy effectively enhances sensor sensitivity, while MCHA decreases the false-positive rate. The aptamer sensor exhibits high specificity, is resistant to interference, and can be used for the detection of Hg2+ and Ag+ in environmental water samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Public Health, Hengyang School of Medicine, University of South China, Hengyang 421001, China.
- State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University, Changsha 410082, China.
- Department of Public Health Laboratory Science, University of South China, Hengyang 421001, China.
Förderung
- This research was supported by the Hunan Provincial Natural Science Foundation of China
- the Scientific Research Project of Hunan Provincial Health Commission
- Hunan Provincial Natural Science Foundation of China
- Scientific Research Project of Hunan Provincial Health Commission
Zitieren
APA
Liu, Z., Liu, X., Sun, J., & Xiao, X. (2025). Cascade Fluorescent Sensors Based on Isothermal Signal Amplification for the Detection of Mercury and Silver Ions. Biosensors. https://doi.org/10.3390/bios15040213
Vancouver
Liu Z, Liu X, Sun J, Xiao X. Cascade Fluorescent Sensors Based on Isothermal Signal Amplification for the Detection of Mercury and Silver Ions. Biosensors. 2025. doi:10.3390/bios15040213
BibTeX
@article{Liu2025,
author = {Liu, Zhen and Liu, Xing and Sun, Jie and Xiao, Xilin},
title = {Cascade Fluorescent Sensors Based on Isothermal Signal Amplification for the Detection of Mercury and Silver Ions},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15040213}
}
EUVIMED