A Review of Readout Circuit Schemes Using Silicon Nanowire Ion-Sensitive Field-Effect Transistors for pH-Sensing Applications
Biosensors · 2025
DOI: 10.3390/bios15040206 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Biosensors, 2025. Verfasst von Jungho Joo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Intelligent Semiconductor and Display Engineering, Kookmin University, Seoul 02707, Republic of Korea. Hauptthemen laut MEDLINE: Nanowires, Silicon, Biosensing Techniques, Transistors, Electronic. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 120 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Research Foundation of Korea (NRF), Institute of Information & Communications Technology Planning & Evaluation (IITP).
Abstract (Originalsprache)
This paper reviews various design approaches for sensing schemes that utilize silicon nanowire (SiNW) ion-sensitive field-effect transistors (ISFETs) for pH-sensing applications. SiNW ISFETs offer advantageous characteristics, including a high surface-to-volume ratio, fast response time, and suitability for integration with complementary metal oxide semiconductor (CMOS) technology. This review focuses on SiNW ISFET-based biosensors in three key aspects: (1) major fabrication processes and device structures; (2) theoretical analysis of key performance parameters in readout circuits such as sensitivity, linearity, noise immunity, and output range in different system configurations; and (3) an overview of existing readout circuits with quantitative evaluations of N-type and P-type current-mirror-based circuits, highlighting their strengths and limitations. Finally, this paper proposes a modified N-type readout scheme integrating an operational amplifier with a negative feedback network to overcome the low sensitivity of conventional N-type circuits. This design enhances gain control, linearity, and noise immunity while maintaining stability. These advancements are expected to contribute to the advancement of the current state-of-the-art SiNW ISFET-based readout circuits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Intelligent Semiconductor and Display Engineering, Kookmin University, Seoul 02707, Republic of Korea.
- School of Electrical Engineering, Kookmin University, Seoul 02707, Republic of Korea.
- Department of Artificial Intelligence Semiconductor Engineering, Hanyang University, Seoul 04763, Republic of Korea.
- Department of Electronic Engineering, Hanyang University, Seoul 04763, Republic of Korea.
ORCID-Profile: Seonho Shin, Ickhyun Song, Dae Hwan Kim
Förderung
- National Research Foundation of Korea (NRF)
- Institute of Information & Communications Technology Planning & Evaluation (IITP)
Zitieren
APA
Joo, J., Mo, H., Kim, S., Shin, S., Song, I., & Kim, D. H. (2025). A Review of Readout Circuit Schemes Using Silicon Nanowire Ion-Sensitive Field-Effect Transistors for pH-Sensing Applications. Biosensors. https://doi.org/10.3390/bios15040206
Vancouver
Joo J, Mo H, Kim S, Shin S, Song I, Kim DH. A Review of Readout Circuit Schemes Using Silicon Nanowire Ion-Sensitive Field-Effect Transistors for pH-Sensing Applications. Biosensors. 2025. doi:10.3390/bios15040206
BibTeX
@article{Joo2025,
author = {Joo, Jungho and Mo, Hyunsun and Kim, Seungguk and Shin, Seonho and Song, Ickhyun and Kim, Dae Hwan},
title = {A Review of Readout Circuit Schemes Using Silicon Nanowire Ion-Sensitive Field-Effect Transistors for pH-Sensing Applications},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15040206}
}
EUVIMED