Equivalent Circuit Modeling and Analysis for Microfluidic Electrical Impedance Monitoring of Single-Cell Growth
Biosensors · 14.02.2025 · 15 (2) · 113
DOI: 10.3390/bios15020113 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 14.02.2025. Verfasst von Yingying Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Integrated Circuits, Southeast University, Wuxi Campus, Zhuangyuan Road 5, Wuxi 214000, China. Hauptthemen laut MEDLINE: Single-Cell Analysis, Biosensing Techniques, Microfluidics. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Key R&D Program of China, National Natural Science Foundation of China, Natural Science Foundation of Jiangsu Province.
Abstract (Originalsprache)
Microfluidics has significantly advanced the field of single-cell analysis, particularly in studies related to cell growth, division, and heterogeneity. Electrical impedance spectroscopy (EIS), a label-free and non-invasive biosensing technique, has been integrated into microfluidic devices for high-throughput and long-term monitoring of single budding yeast cells. Accurate interpretation of EIS measurements of cell growth dynamics necessitates the establishment of theoretical equivalent circuit models for the single-cell sensing system. Here, we report on the development of equivalent circuit models of an in situ EIS sensing system to elucidate cell growth. Firstly, finite element modeling and simulation of an EIS measurement of cell growth in the EIS sensing unit were performed, guiding the fittings of electrical components for an established equivalent circuit model (ECM). From the ECM, we extracted an equivalent volume fraction applicable to various cell and sensing unit geometries to describe the geometry-dependent sensing characteristics corresponding to the electrical response in the model. Then, EIS measurements of an immobilized cell in a microfluidic device were conducted via peripheral circuits. A lumped parameter model for the entire EIS measurement system was established, with electrical components determined by fitting to experimental data. The rationality of the proposed theoretical model was validated through the long-term impedance variation induced by cell growth in experiments, demonstrating its feasibility in linking EIS data with the bio-physics underlying the experimental phenomenon.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Integrated Circuits, Southeast University, Wuxi Campus, Zhuangyuan Road 5, Wuxi 214000, China.
- College of Chemical Engineering, Nanjing Forestry University, Longpan Road 159, Nanjing 210037, China.
ORCID-Profile: Zhao Zhang, Zhen Zhu
Förderung
- National Key R&D Program of China
- National Natural Science Foundation of China
- Natural Science Foundation of Jiangsu Province
- Fundamental Research Funds for Central Universities
- the National Key R&D Program of China
- the National Natural Science Foundation of China
- the Natural Science Foundation of Jiangsu Province
- the Fundamental Research Funds for Central Universities
Zitieren
APA
Wang, Y., Wu, H., Geng, Y., Zhang, Z., Fu, J., Ouyang, J., & Zhu, Z. (2025). Equivalent Circuit Modeling and Analysis for Microfluidic Electrical Impedance Monitoring of Single-Cell Growth. Biosensors, 15(2), 113. https://doi.org/10.3390/bios15020113
Vancouver
Wang Y, Wu H, Geng Y, Zhang Z, Fu J, Ouyang J, et al. Equivalent Circuit Modeling and Analysis for Microfluidic Electrical Impedance Monitoring of Single-Cell Growth. Biosensors. 2025;15(2):113. doi:10.3390/bios15020113
BibTeX
@article{Wang2025,
author = {Wang, Yingying and Wu, Haoran and Geng, Yulu and Zhang, Zhao and Fu, Jiaming and Ouyang, Jia and Zhu, Zhen},
title = {Equivalent Circuit Modeling and Analysis for Microfluidic Electrical Impedance Monitoring of Single-Cell Growth},
journal = {Biosensors},
year = {2025},
volume = {15},
number = {2},
pages = {113},
doi = {10.3390/bios15020113}
}
EUVIMED