Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum

Kuan-Hsun Huang iD, Cheng-Xue Yu iD, Chia-Chun Lee, Chin-Chung Tseng iD, Lung-Ming Fu iD

Biosensors · 2025

DOI: 10.3390/bios15020104 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Kuan-Hsun Huang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan. Hauptthemen laut MEDLINE: Sodium, Point-of-Care Systems, Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Science and Technology Council of Taiwan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A microfluidic system for detecting sodium ions (Na+) has been developed, incorporating a micro finger-pump chip and a micro-spectrometer platform to measure Na+ concentration in human serum. A small volume (10 μL) of serum sample is introduced into the microchip and reacted with a preloaded reagent mixture through a two-step finger-pump actuation process. The resulting purple complex is directed into the detection area of the chip and analyzed using the micro-spectrometer at wavelengths of 555 and 666 nm. The Na+ concentration is then inversely derived from the measured A555/A666 absorbance ratio using self-written software installed on a Raspberry Pi. The entire detection process is completed in just 3 min, offering a significant advantage in meeting clinical needs compared to the traditional reporting turnaround time of several hours in medical institutions. The experimental results indicate a linear relationship between the measured absorbance ratio and Na+ concentration within the range of 1–200 mM, with a correlation coefficient of R2 = 0.9989. Additionally, the detection results from 60 serum samples collected from chronic kidney disease (CKD) patients showed a strong agreement with those obtained using the conventional indirect ion-selective electrode (ISE) method, achieving a correlation coefficient of R2 = 0.9885 and an average recovery rate of 99.4%. In summary, the proposed system provides a practical, affordable, and rapid alternative to conventional Na+ detection methods, making it highly promising for point-of-care (POC) testing applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SodiumPoint-of-Care SystemsBiosensing TechniquesHumans

Stichwörter der Autor:innen

chronic kidney diseasefinger pumpmicro-spectrometermicrofluidicsodium

Substanzen

Sodium

Autor:innen und Institutionen

  • Department of Engineering Science, National Cheng Kung University, Tainan 701, Taiwan.
  • Division of Nephrology, Department of Internal Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan.
  • Institute of Clinical Medicine, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan.

ORCID-Profile: Kuan-Hsun Huang, Cheng-Xue Yu, Chin-Chung Tseng, Lung-Ming Fu

Förderung

  • National Science and Technology Council of Taiwan

Zitieren

APA

Huang, K. H., Yu, C. X., Lee, C. C., Tseng, C. C., & Fu, L. M. (2025). Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum. Biosensors. https://doi.org/10.3390/bios15020104

Vancouver

Huang KH, Yu CX, Lee CC, Tseng CC, Fu LM. Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum. Biosensors. 2025. doi:10.3390/bios15020104

BibTeX
@article{Huang2025,
  author = {Huang, Kuan-Hsun and Yu, Cheng-Xue and Lee, Chia-Chun and Tseng, Chin-Chung and Fu, Lung-Ming},
  title = {Rapid Microfluidic Ion-Exchange Optode System for Point-of-Care Determination of Sodium Concentration in Serum},
  journal = {Biosensors},
  year = {2025},
  doi = {10.3390/bios15020104}
}