Application of Wearable Insole Sensors in In-Place Running: Estimating Lower Limb Load Using Machine Learning
Biosensors · 2025
DOI: 10.3390/bios15020083 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Shipan Lang und 7 weiteren Autor:innen. Beteiligte Einrichtung: College of Computer and Information Science & College of Software, Southwest University, Chongqing 400715, China. Hauptthemen laut MEDLINE: Machine Learning, Wearable Electronic Devices, Running, Lower Extremity. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Science and Technology Research Program of Chongqing Municipal Education Commission.
Abstract (Originalsprache)
Musculoskeletal injuries induced by high-intensity and repetitive physical activities represent one of the primary health concerns in the fields of public fitness and sports. Musculoskeletal injuries, often resulting from unscientific training practices, are particularly prevalent, with the tibia being especially vulnerable to fatigue-related damage. Current tibial load monitoring methods rely mainly on laboratory equipment and wearable devices, but datasets combining both sources are limited due to experimental complexities and signal synchronization challenges. Moreover, wearable-based algorithms often fail to capture deep signal features, hindering early detection and prevention of tibial fatigue injuries. In this study, we simultaneously collected data from laboratory equipment and wearable insole sensors during in-place running by volunteers, creating a dataset named WearLab-Leg. Based on this dataset, we developed a machine learning model integrating Temporal Convolutional Network (TCN) and Transformer modules to estimate vertical ground reaction force (vGRF) and tibia bone force (TBF) using insole pressure signals. Our model’s architecture effectively combines the advantages of local deep feature extraction and global modeling, and further introduces the Weight-MSELoss function to improve peak prediction performance. As a result, the model achieved a normalized root mean square error (NRMSE) of 7.33% for vGRF prediction and 10.64% for TBF prediction. Our dataset and proposed model offer a convenient solution for biomechanical monitoring in athletes and patients, providing reliable data and technical support for early warnings of fatigue-induced injuries.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- College of Computer and Information Science & College of Software, Southwest University, Chongqing 400715, China.
- Chongqing Institute of Green and Intelligent Technology, Chinese Academy of Sciences, Chongqing 400714, China.
- Department of Orthopedics, The Chinese PLA General Hospital, Beijing 100039, China.
Förderung
- National Natural Science Foundation of China
- Science and Technology Research Program of Chongqing Municipal Education Commission
Zitieren
APA
Lang, S., Yang, J., Zhang, Y., Li, P., Gou, X., Chen, Y., Li, C., & Zhang, H. (2025). Application of Wearable Insole Sensors in In-Place Running: Estimating Lower Limb Load Using Machine Learning. Biosensors. https://doi.org/10.3390/bios15020083
Vancouver
Lang S, Yang J, Zhang Y, Li P, Gou X, Chen Y, et al. Application of Wearable Insole Sensors in In-Place Running: Estimating Lower Limb Load Using Machine Learning. Biosensors. 2025. doi:10.3390/bios15020083
BibTeX
@article{Lang2025,
author = {Lang, Shipan and Yang, Jun and Zhang, Yong and Li, Pei and Gou, Xin and Chen, Yuanzhu and Li, Chunbao and Zhang, Heng},
title = {Application of Wearable Insole Sensors in In-Place Running: Estimating Lower Limb Load Using Machine Learning},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15020083}
}
EUVIMED