A Microfluidic Paper-Based Device for Monitoring Urease Activity in Saliva
Biosensors · 2025
DOI: 10.3390/bios15010048 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2025. Verfasst von Francisca T S M Ferreira und 2 weiteren Autor:innen. Beteiligte Einrichtung: CBQF-Centro de Biotecnologia e Química Fina, Laboratório Associado, Universidade Católica Portuguesa, Escola Superior de Biotecnologia, Rua Diogo Bot…. Hauptthemen laut MEDLINE: Saliva, Urease, Lab-On-A-Chip Devices, Biosensing Techniques. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fundação para a Ciência e Tecnologia.
Abstract (Originalsprache)
Chronic Kidney Disease (CKD) is a disorder that affects over 10% of the global population, and that would benefit from innovative methodologies that would provide early detection. Since it has been reported that there are high levels of urease in CKD patients’ saliva, this sample is a promising non-invasive alternative to blood for CKD detection and monitoring. This work introduces a novel 3D µPAD for quantifying urease activity in saliva in a range of 0.041–0.750 U/mL, with limits of detection and quantification of 0.012 and 0.041 U/mL, respectively. The device uses the urease in the sample to convert urea into ammonia, causing a colorimetric change in the bromothymol blue. The accuracy of the developed device was evaluated by comparing the measurements of several saliva samples (#13) obtained with the μPAD and with a commercially available kit. Stability studies were also performed to assess its functionality as a point-of-care methodology, and the device was stable for 4 months when stored in a vacuum. After the sample placement, it could be scanned within 40 min without providing significantly different results. The developed device quantifies urease activity in saliva within 30 min, providing a simple, portable, lab-free alternative to existing methodologies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- CBQF-Centro de Biotecnologia e Química Fina, Laboratório Associado, Universidade Católica Portuguesa, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal.
ORCID-Profile: Raquel B R Mesquita
Förderung
- Fundação para a Ciência e Tecnologia
Zitieren
APA
Ferreira, F. T. S. M., Rangel, A. O. S. S., & Mesquita, R. B. R. (2025). A Microfluidic Paper-Based Device for Monitoring Urease Activity in Saliva. Biosensors. https://doi.org/10.3390/bios15010048
Vancouver
Ferreira FTSM, Rangel AOSS, Mesquita RBR. A Microfluidic Paper-Based Device for Monitoring Urease Activity in Saliva. Biosensors. 2025. doi:10.3390/bios15010048
BibTeX
@article{Ferreira2025,
author = {Ferreira, Francisca T S M and Rangel, António O S S and Mesquita, Raquel B R},
title = {A Microfluidic Paper-Based Device for Monitoring Urease Activity in Saliva},
journal = {Biosensors},
year = {2025},
doi = {10.3390/bios15010048}
}