EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Glucose Sensor Design Based on Monte Carlo Simulation

Gang Xue, Ruiping Zhang iD, Yihao Chen, Wei Xu, Changxing Zhang iD

Biosensors · 04.01.2025 · 15 (1) · 17

DOI: 10.3390/bios15010017 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 04.01.2025. Verfasst von Gang Xue und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous glucose monitoring based on the minimally invasive implantation of glucose sensor is characterized by high accuracy and good stability. At present, glucose concentration monitoring based on fluorescent glucose capsule sensor is a new development trend. In this paper, we design a fluorescent glucose capsule sensor with a design optimization study. The motion trajectory of incident light in the fluorescent gel layer is simulated based on the Monte Carlo method, and the cloud maps of light intensity with the light intensity distribution at the light-receiving layer are plotted. Altering the density of fluorescent molecules, varying the thickness of tissue layers, and adjusting the angle of incidence deflection, the study investigates the influence of these parameter changes on the optimal position of reflected light at the bottom. Finally, the simulation results were utilized to design and fabricate a fluorescent glucose capsule sensor. Rabbit subcutaneous tissue glucose level tests and real-time glucose solution concentration monitoring experiments were performed. This work contributes to the real-time monitoring of glucose levels and opens up new avenues for research on fabricating glucose sensors.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGlucoseMonte Carlo MethodAnimalsRabbitsBlood GlucoseEquipment Design

Stichwörter der Autor:innen

Monte Carlo simulationbiosensorglucose sensorreal-time monitoring

Substanzen

GlucoseBlood Glucose

Autor:innen und Institutionen

  • Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China.
  • Intelligent Infrastructure Operation and Maintenance Technology Innovation Team of Yunnan Provincial Department of Education, Kunming University of Science and Technology, Kunming 650500, China.
  • Laboratory of Flexible Electronics Technology, Tsinghua University, Beijing 100084, China.
  • Key Laboratory of Applied Mechanics, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China.

ORCID-Profile: Ruiping Zhang, Changxing Zhang

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Xue, G., Zhang, R., Chen, Y., Xu, W., & Zhang, C. (2025). Glucose Sensor Design Based on Monte Carlo Simulation. Biosensors, 15(1), 17. https://doi.org/10.3390/bios15010017

Vancouver

Xue G, Zhang R, Chen Y, Xu W, Zhang C. Glucose Sensor Design Based on Monte Carlo Simulation. Biosensors. 2025;15(1):17. doi:10.3390/bios15010017

BibTeX
@article{Xue2025,
  author = {Xue, Gang and Zhang, Ruiping and Chen, Yihao and Xu, Wei and Zhang, Changxing},
  title = {Glucose Sensor Design Based on Monte Carlo Simulation},
  journal = {Biosensors},
  year = {2025},
  volume = {15},
  number = {1},
  pages = {17},
  doi = {10.3390/bios15010017}
}