A Microfluidic Biosensor for Quantitative Detection of Salmonella in Traditional Chinese Medicine
Biosensors · 2024
DOI: 10.3390/bios15010010 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Yutong Wu und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Salmonella, Medicine, Chinese Traditional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities of China.
Abstract (Originalsprache)
Microbial contamination is an important factor threatening the safety of Chinese medicine preparations, and microfluidic detection methods have demonstrated excellent advantages in the application of rapid bacterial detection. In our study, a novel optical biosensor was developed for the rapid and sensitive detection of Salmonella in traditional Chinese medicine on a microfluidic chip. Immune gold@platinum nanocatalysts (Au@PtNCs) were utilized for specific bacterial labeling, while magnetic nano-beads (MNBs) with a novel high-gradient magnetic field were employed for the specific capture of bacteria. The immune MNBs, immune Au@PtNCs, and bacterial samples were introduced into a novel passive microfluidic micromixer for full mixing, resulting in the formation of a double-antibody sandwich structure due to antigen–antibody immune reactions. Subsequently, the mixture flowed into the reaction cell, where the MNBs-Salmonella-Au@PtNCs complex was captured by the magnetic field. After washing, hydrogen peroxide-tetramethylbenzidine substrate (H2O2-TMB) was added, reacting with the Au@PtNCs peroxidase to produce a blue reaction product. This entire process was automated using a portable device, and Salmonella concentration was analyzed via a phone application. This simple biosensor has good specificity with a detection range of 9 × 101–9 × 105 CFU/mL and can detect Salmonella concentrations as low as 90 CFU/mL within 74 min. The average recoveries of the spiked samples ranged from 76.8% to 109.5%
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China.
- School of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan 250355, China.
- China Center for Information Industry Development, Beijing 100036, China.
- Fangshan Hospital of Beijing University of Chinese Medicine, Beijing 102400, China.
- Dongzhimen Hospital of Beijing University of Chinese Medicine, Beijing 100700, China.
ORCID-Profile: Wuzhen Qi
Förderung
- National Natural Science Foundation of China
- Fundamental Research Funds for the Central Universities of China
Zitieren
APA
Wu, Y., Liu, Y., Ma, J., Zhu, S., Zhao, X., Mou, H., Ke, X., Wu, Z., Wang, Y., Lin, S., & Qi, W. (2024). A Microfluidic Biosensor for Quantitative Detection of Salmonella in Traditional Chinese Medicine. Biosensors. https://doi.org/10.3390/bios15010010
Vancouver
Wu Y, Liu Y, Ma J, Zhu S, Zhao X, Mou H, et al. A Microfluidic Biosensor for Quantitative Detection of Salmonella in Traditional Chinese Medicine. Biosensors. 2024. doi:10.3390/bios15010010
BibTeX
@article{Wu2024,
author = {Wu, Yutong and Liu, Yang and Ma, Jinchen and Zhu, Shanxi and Zhao, Xiaojun and Mou, Huawei and Ke, Xuanqi and Wu, Zhisheng and Wang, Yifei and Lin, Sheng and Qi, Wuzhen},
title = {A Microfluidic Biosensor for Quantitative Detection of Salmonella in Traditional Chinese Medicine},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios15010010}
}
EUVIMED