EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development of RT h-CLAT, a Rapid Assessment Method for Skin Sensitizers Using THP-1 Cells as a Biosensor

Hiroki Koyama, Ayami Maeda, Peiqi Zhai, Keiichiro Koiwai iD, Kouichi Kurose iD

Biosensors · 2024

DOI: 10.3390/bios14120632 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Hiroki Koyama und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Food Science and Technology, Tokyo University of Marine Science and Technology, Tokyo 108-8477, Japan. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: JSPS KAKENHI.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent years, in vitro skin sensitization assays have been recommended as animal-free alternatives for the safety assessment of cosmetics and topical drugs, and these methods have been adopted in OECD test guidelines. However, existing assays remain complex and costly. To address this, we recently developed a more efficient, cost-effective, and accurate method for evaluating skin sensitizers by using immune cell-derived THP-1 cells as a biosensor, coupled with an RT-PCR-based assay. In this study, we further refined this method to enable even faster assessment of skin sensitization. By performing comprehensive RNA sequencing (RNA-Seq) analysis, we examined gene expression profiles induced by sensitizers in THP-1 cells to identify potential sensitization markers, ultimately selecting the optimal markers and conditions for evaluation. Our findings indicate that after exposing a test chemical to THP-1 cells for 5 h, measuring the expression levels of the JUN and HMOX1 genes via real-time PCR allows for a reliable assessment of sensitization. A test compound is defined as a sensitizer if either gene shows a more than two-fold increase in its expression compared to the control. Applying this improved method, designated as RT h-CLAT, we evaluated the sensitization potential of 43 chemicals. The results demonstrated higher accuracy compared to the human cell line activation test (h-CLAT) listed in the OECD guidelines, while also reducing the required assessment time from two days to one.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesHumansTHP-1 CellsSkinAllergens

Stichwörter der Autor:innen

HMOX1JUNRNA-Seq analysisalternative methodsbiomarkerin vitro skin sensitization test

Substanzen

Allergens

Autor:innen und Institutionen

  • Department of Food Science and Technology, Tokyo University of Marine Science and Technology, Tokyo 108-8477, Japan.
  • Department of Marine Biosciences, Tokyo University of Marine Science and Technology, Tokyo 108-8477, Japan.

ORCID-Profile: Keiichiro Koiwai, Kouichi Kurose

Förderung

  • JSPS KAKENHI

Zitieren

APA

Koyama, H., Maeda, A., Zhai, P., Koiwai, K., & Kurose, K. (2024). Development of RT h-CLAT, a Rapid Assessment Method for Skin Sensitizers Using THP-1 Cells as a Biosensor. Biosensors. https://doi.org/10.3390/bios14120632

Vancouver

Koyama H, Maeda A, Zhai P, Koiwai K, Kurose K. Development of RT h-CLAT, a Rapid Assessment Method for Skin Sensitizers Using THP-1 Cells as a Biosensor. Biosensors. 2024. doi:10.3390/bios14120632

BibTeX
@article{Koyama2024,
  author = {Koyama, Hiroki and Maeda, Ayami and Zhai, Peiqi and Koiwai, Keiichiro and Kurose, Kouichi},
  title = {Development of RT h-CLAT, a Rapid Assessment Method for Skin Sensitizers Using THP-1 Cells as a Biosensor},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14120632}
}
Kostenlos starten →