Ultrasensitive Lateral Flow Immunoassay of Fluoroquinolone Antibiotic Gatifloxacin Using Au@Ag Nanoparticles as a Signal-Enhancing Label
Biosensors · 2024
DOI: 10.3390/bios14120598 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Olga D Hendrickson und 8 weiteren Autor:innen. Beteiligte Einrichtung: A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia. Hauptthemen laut MEDLINE: Gold, Metal Nanoparticles, Silver, Gatifloxacin. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Russian Science Foundation.
Abstract (Originalsprache)
Gatifloxacin (GAT), an antibiotic belonging to the fluoroquinolone (FQ) class, is a toxicant that may contaminate food products. In this study, a method of ultrasensitive immunochromatographic detection of GAT was developed for the first time. An indirect format of the lateral flow immunoassay (LFIA) was performed. GAT-specific monoclonal antibodies and labeled anti-species antibodies were used in the LFIA. Bimetallic core@shell Au@Ag nanoparticles (Au@Ag NPs) were synthesized as a new label. Peroxidase-mimic properties of Au@Ag NPs allowed for the catalytic enhancement of the signal on test strips, increasing the assay sensitivity. A mechanism of Au@Ag NPs-mediated catalysis was deduced. Signal amplification was achieved through the oxidative etching of Au@Ag NPs by hydrogen peroxide. This resulted in the formation of gold nanoparticles and Ag+ ions, which catalyzed the oxidation of the peroxidase substrate. Such “chemical enhancement” allowed for reaching the instrumental limit of detection (LOD, calculated by Three Sigma approach) and cutoff of 0.8 and 20 pg/mL, respectively. The enhanced assay procedure can be completed in 21 min. The enhanced LFIA was tested for GAT detection in raw meat samples, and the recoveries from meat were 78.1–114.8%. This method can be recommended as a promising instrument for the sensitive detection of various toxicants.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky Prospect 33, 119071 Moscow, Russia.
- Department of Chemistry, Waterloo Institute for Nanotechnology, Waterloo, ON N2L 3G1, Canada.
- Guangdong Provincial Key Laboratory of Food Quality and Safety, College of Food Science, South China Agricultural University, Guangzhou 510642, China.
ORCID-Profile: Olga D Hendrickson, Shen Xing, Anatoly V Zherdev, Juewen Liu, Hongtao Lei, Boris B Dzantiev
Förderung
- Russian Science Foundation
Zitieren
APA
Hendrickson, O. D., Byzova, N. A., Panferov, V. G., Zvereva, E. A., Xing, S., Zherdev, A. V., Liu, J., Lei, H., & Dzantiev, B. B. (2024). Ultrasensitive Lateral Flow Immunoassay of Fluoroquinolone Antibiotic Gatifloxacin Using Au@Ag Nanoparticles as a Signal-Enhancing Label. Biosensors. https://doi.org/10.3390/bios14120598
Vancouver
Hendrickson OD, Byzova NA, Panferov VG, Zvereva EA, Xing S, Zherdev AV, et al. Ultrasensitive Lateral Flow Immunoassay of Fluoroquinolone Antibiotic Gatifloxacin Using Au@Ag Nanoparticles as a Signal-Enhancing Label. Biosensors. 2024. doi:10.3390/bios14120598
BibTeX
@article{Hendrickson2024,
author = {Hendrickson, Olga D and Byzova, Nadezhda A and Panferov, Vasily G and Zvereva, Elena A and Xing, Shen and Zherdev, Anatoly V and Liu, Juewen and Lei, Hongtao and Dzantiev, Boris B},
title = {Ultrasensitive Lateral Flow Immunoassay of Fluoroquinolone Antibiotic Gatifloxacin Using Au@Ag Nanoparticles as a Signal-Enhancing Label},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14120598}
}
EUVIMED