A Reflective Terahertz Point Source Meta-Sensor with Asymmetric Meta-Atoms for High-Sensitivity Bio-Sensing
Biosensors · 2024
DOI: 10.3390/bios14120568 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Luwei Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Laser Engineering, Osaka University, Suita 565-0871, Osaka, Japan. Hauptthemen laut MEDLINE: Biosensing Techniques. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 76 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Science and Technology Agency, Japan Society for the Promotion of Science, China Scholarship Council.
Abstract (Originalsprache)
Biosensors operating in the terahertz (THz) region are gaining substantial interest in biomedical analysis due to their significant potential for high-sensitivity trace-amount solution detection. However, progress in compact, high-sensitivity chips and methods for simple, rapid and trace-level measurements is limited by the spatial resolution of THz waves and their strong absorption in polar solvents. In this work, a compact nonlinear optical crystal (NLOC)-based reflective THz biosensor with a few arrays of asymmetrical meta-atoms was developed. A near-field point THz source was locally generated at a femtosecond-laser-irradiation spot via optical rectification, exciting only the single central meta-atom, thereby inducing Fano resonance. The reflective resonance response demonstrated dependence on several aspects, including structure asymmetricity, geometrical size, excitation point position, thickness and array-period arrangement. DNA samples were examined using 1 μL applied to an effective sensing area of 0.234 mm2 (484 μm × 484 μm) for performance evaluation. The developed Fano resonance sensor exhibited nearly double sensitivity compared to that of symmetrical sensors and one-gap split ring resonators. Thus, this study advances liquid-based sensing by enabling easy, rapid and trace-level measurements while also driving the development of compact and highly sensitive THz sensors for biological samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Institute of Laser Engineering, Osaka University, Suita 565-0871, Osaka, Japan.
- Graduate School of Information, Production, and Systems, Waseda University, Kitakyusyu 808-0135, Fukuoka, Japan.
ORCID-Profile: Hironaru Murakami, Masayoshi Tonouchi, Kazunori Serita
Förderung
- Japan Science and Technology Agency
- Japan Society for the Promotion of Science
- China Scholarship Council
- Fusion Oriented Research for Disruptive Science and Technology
- JSPS KAKENHI
Zitieren
APA
Zheng, L., Hara, K., Murakami, H., Tonouchi, M., & Serita, K. (2024). A Reflective Terahertz Point Source Meta-Sensor with Asymmetric Meta-Atoms for High-Sensitivity Bio-Sensing. Biosensors. https://doi.org/10.3390/bios14120568
Vancouver
Zheng L, Hara K, Murakami H, Tonouchi M, Serita K. A Reflective Terahertz Point Source Meta-Sensor with Asymmetric Meta-Atoms for High-Sensitivity Bio-Sensing. Biosensors. 2024. doi:10.3390/bios14120568
BibTeX
@article{Zheng2024,
author = {Zheng, Luwei and Hara, Kazuki and Murakami, Hironaru and Tonouchi, Masayoshi and Serita, Kazunori},
title = {A Reflective Terahertz Point Source Meta-Sensor with Asymmetric Meta-Atoms for High-Sensitivity Bio-Sensing},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14120568}
}