A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples

Michelle T Tran iD, Sophia V Gomez, Vera Alenicheva iD, Vincent T Remcho iD

Biosensors · 2024

DOI: 10.3390/bios14110559 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Michelle T Tran und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, Oregon State University, Corvallis, OR 97331, USA. Hauptthemen laut MEDLINE: Antioxidants, Paper. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 56 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NASA, NASA Space Technology Graduate Research Opportunity.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Determining the total antioxidant capacity (TAC) of biological samples is a valuable approach to measuring health status under oxidative stress conditions, such as infertility and type 2 diabetes. The Trolox equivalent antioxidant capacity (TEAC) assay is the most common approach to evaluating TAC in biological matrices. This assay is typically performed in clinical settings on a microtiter plate using a plate reader. However, the instrumentation and expertise requirements, and the resulting delay in the reporting of assay outcomes, make solution-based TEAC assays impractical for point-of-care or at-home testing, where individuals may want to monitor their health status during treatment. This work introduces the first microfluidic paper-based analytical device (µPAD) that measures TAC in human serum using TEAC assay chemistry. TAC was determined through a colorimetric image analysis of the degree of decolorization of 2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) radical cations (ABTS●+) by serum antioxidants. The µPAD showed a linear response to Trolox, ranging from 0.44 to 2.4 mM, (r = 0.999). The performance of paper-based TEAC assays was validated through direct comparison to solution-based TEAC assays. There was a 0.04 mM difference in TAC values between the two platforms, well within one standard deviation of a standard solution-based assay conducted on an aliquot of the same serum sample (±0.25 mM). The µPAD had a limit of detection (LOD) of 0.20 mM, well below the TAC of normal human serum. The results suggest that the proposed device can be used for biological TAC determination and expands the field of TAC analysis in point-of-care health monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AntioxidantsPaperHumansColorimetryBenzothiazolesSulfonic AcidsOxidative Stress

Stichwörter der Autor:innen

2,2′-azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS)Trolox equivalent antioxidant capacity (TEAC)antioxidantmicrofluidic paper-based analytical device (µPAD)total antioxidant capacity (TAC)

Substanzen

AntioxidantsBenzothiazoles2,2'-azino-di-(3-ethylbenzothiazoline)-6-sulfonic acidSulfonic Acids

Autor:innen und Institutionen

  • Department of Chemistry, Oregon State University, Corvallis, OR 97331, USA.

ORCID-Profile: Michelle T Tran, Vera Alenicheva, Vincent T Remcho

Förderung

  • NASA
  • NASA Space Technology Graduate Research Opportunity

Zitieren

APA

Tran, M. T., Gomez, S. V., Alenicheva, V., & Remcho, V. T. (2024). A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples. Biosensors. https://doi.org/10.3390/bios14110559

Vancouver

Tran MT, Gomez SV, Alenicheva V, Remcho VT. A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples. Biosensors. 2024. doi:10.3390/bios14110559

BibTeX
@article{Tran2024,
  author = {Tran, Michelle T and Gomez, Sophia V and Alenicheva, Vera and Remcho, Vincent T},
  title = {A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14110559}
}
Kostenlos starten →