A Novel High-Throughput Sample-in-Result-Out Device for the Rapid Detection of Viral Nucleic Acids
Biosensors · 13.11.2024 · 14 (11) · 549
DOI: 10.3390/bios14110549 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors, online erschienen am 13.11.2024. Verfasst von Fangning Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory for Manufacturing Systems Engineering, School of Instrument Science and Techonology, Xi'an Jiaotong University, Xi'an 710054, Ch…. Hauptthemen laut MEDLINE: SARS-CoV-2. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, Key Research and Development Program of China, Shaanxi Province Key R&D Program.
Abstract (Originalsprache)
Clustered regularly interspaced short palindromic repeats (CRISPR) molecular diagnostic technology is one of the most reliable diagnostic tools for infectious diseases due to its short reaction time, high sensitivity, and excellent specificity. However, compared with fluorescent polymerase chain reaction (PCR) technology, CRISPR molecular diagnostic technology lacks high-throughput automated instrumentation and standardized detection reagents for high sensitivity, limiting its large-scale clinical application. In this study, a high-throughput automated device was developed by combining reagent lyophilization, extraction-free technology, and a one-pot consumable system. This innovative approach enabled the rapid sample-in-result-out detection of 48 samples in 25 min and demonstrated high sensitivity and specificity for the qualitative analysis of clinical samples. The obtained results show that the detection limit of the designed system for African swine fever virus (ASFV) is 0.5 copies/μL. As a proof concept, a single-tube dual-target nucleic acid detection method was developed, achieving a detection limit of 5 copies/μL for the ORF1ab and N genes of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) within 45 min. The method is highly specific, reliable, and stable, providing a feasible solution for the clinical application of CRISPR nucleic acid detection technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory for Manufacturing Systems Engineering, School of Instrument Science and Techonology, Xi'an Jiaotong University, Xi'an 710054, China.
ORCID-Profile: Fangning Wang
Förderung
- National Natural Science Foundation of China
- Key Research and Development Program of China
- Shaanxi Province Key R&D Program
- Shaanxi Province Key R&D Program
Zitieren
APA
Wang, F., Hu, F., Zhang, Y., Li, X., Ma, Q., Wang, X., & Peng, N. (2024). A Novel High-Throughput Sample-in-Result-Out Device for the Rapid Detection of Viral Nucleic Acids. Biosensors, 14(11), 549. https://doi.org/10.3390/bios14110549
Vancouver
Wang F, Hu F, Zhang Y, Li X, Ma Q, Wang X, et al. A Novel High-Throughput Sample-in-Result-Out Device for the Rapid Detection of Viral Nucleic Acids. Biosensors. 2024;14(11):549. doi:10.3390/bios14110549
BibTeX
@article{Wang2024,
author = {Wang, Fangning and Hu, Fei and Zhang, Yunyun and Li, Xichen and Ma, Qin and Wang, Xincheng and Peng, Niancai},
title = {A Novel High-Throughput Sample-in-Result-Out Device for the Rapid Detection of Viral Nucleic Acids},
journal = {Biosensors},
year = {2024},
volume = {14},
number = {11},
pages = {549},
doi = {10.3390/bios14110549}
}
EUVIMED